Technical data
41 |
E N
Battery type
3 x 1.5 V AA LR06 alkaline batteries
Duracell Procell MN1500, Duracell Industrial ID1500,
Energizer E91
Battery life
over 2 years
Standby time of the
energy storage system
Type W
(EN 50131-4:2009 Section 5.6.3.2) for battery operation
only, without external power supply via power supply unit.
Operating frequency
868.6625 MHz narrow band
Wireless power output
max. 10 mW
Transmission and
reception range
up to 1000 m range outdoors
Wireless identification
Wireless components, differentiation
16,777,214 (2
24
-2) different IDs
Supervision notification
approx. every 4 minutes
Microwave frequency
9.35 GHz
Microwave transmission
power
Max. 20 mW
Microwave frequency
approved at national
level
Note
The detector with the microwave frequency of 9.35 GHz and a
maximum microwave transmission power of 20 mW
can
be used in
the following countries:
Germany, Austria, Switzerland, Netherlands, Belgium, Denmark
Note
The detector with the microwave frequency of 9.35 GHz and a
maximum microwave transmission power of 20 mW
may not
be
used in the following countries:
UK, France, Italy, Spain, Sweden
Standards for intrusion
and panic button devices
in compliance according to
EN 50131-2-4:2008
(LED walk test disabled)
EN 50131-1:2006+A1:2009+ A2:2017
EN 50131-5-3:2017
EN 50131-6:2017
Security level 2 if installed correctly together with Secvest
FUAA50xxx.
Summary of Contents for FUBW50120
Page 3: ...Inhaltsverzeichnis 3 D E ...
Page 17: ...Position 17 D E ...
Page 33: ...Contents 33 E N ...
Page 47: ...Functional principle and features 47 E N ...
Page 63: ...Table des matières 63 F R ...
Page 77: ...Position 77 F R ...
Page 93: ...Inhoudsopgave 93 N L ...
Page 107: ...Positie 107 N L ...
Page 123: ...Indholdsfortegnelse 123 D A ...
Page 137: ...Position 137 D A ...
Page 153: ...Indice 153 I T ...
Page 167: ...Posizione 167 I T ...
Page 181: ......