Installation
52 |
E N
Note
Thanks to an internal tamper contact, it is not possible to tamper with the housing or
for it to be ripped from a wall.
A moulded part in the recess of the back plate serves as an anti-removal wall contact.
This moulded part is mounted to the wall with screws.
If this is not done, tamper detection for the wall is deactivated.
Step 3: Programming the motion detector
•
Insert the AA batteries provided, ensuring the polarity is correct.
•
Remove the insulation sheet after the batteries have been inserted.
•
Set the receiver component to programming mode. Follow the instructions provided in your
receiver instructions.
Wireless option
•
Trigger the tamper contact of the motion detector to send a tamper message to the receiver
component.
IR option
Note:
The detector’s IR programming mode only lasts for a
short time
after the batteries have been
inserted.
See Chapter “Operation of the LEDs”
•
The IR programming is active if the red LED flashes 4 times.
•
Hold the LED of the motion detector close to the IR receiver of the wireless extension (RFX)
so that the detector can send an IR message to receiver component.
•
Ensure that the motion detector has been recognised by your receiver component.
Summary of Contents for FUBW50120
Page 3: ...Inhaltsverzeichnis 3 D E ...
Page 17: ...Position 17 D E ...
Page 33: ...Contents 33 E N ...
Page 47: ...Functional principle and features 47 E N ...
Page 63: ...Table des matières 63 F R ...
Page 77: ...Position 77 F R ...
Page 93: ...Inhoudsopgave 93 N L ...
Page 107: ...Positie 107 N L ...
Page 123: ...Indholdsfortegnelse 123 D A ...
Page 137: ...Position 137 D A ...
Page 153: ...Indice 153 I T ...
Page 167: ...Posizione 167 I T ...
Page 181: ......