103
Set:
Clicking on this will initiate the process for setting the
limitation (see preview, one after the other: left, right,
upper, lower limitation, iris/ap button for saving)
Delete:
Delete all limitations.
7.7.4 Starting position
Note: the starting positon must be saved as any preset in advance.
Setting for the starting position of the PTZ Dome after restarting
Set:
Set the current position as the starting position.
Delete:
Delete the current starting position.
Go to:
Retrieve a preset (preset position).
7.7.5 Park action
Function for performing a certain action after a defined amount of time (5–720 seconds)
Enable park action:
Enable the function.
Park time:
This is the amount of time that must pass after manual PTZ control
before the park action function can be re-enabled (5–720 seconds).
Auto-scan:
horizontal scan (360°, continuous). The speed can be set from the
basics menu.
Frame scan:
horizontal scan, pausing for 4 seconds every 90°.
Random scan:
scan at random.
Patrol:
start a configured patrol.
Pattern:
start a configured pattern.
Preset:
retrieve a preset (preset position).
Panorama scan:
diagonal scan (360° horizontal, 0~90° vertical, continuous).
Tilt scan:
horizontal scan (0~90°).