PA1018
Fixing set for doors that open outward (Fig. 29).
The fixing set
PA1018
is absolutely essential for a door that opens outward. It involves an
all-through screw fitting, where the reinforced door bar is firmly fixed to the door panel.
The fitting takes place according to the illustration.
Use longer screws for door panel thicknesses exceeding 80 mm (strength of at least 8.8).
With fixed lock bodies using the existing mounting locks that are accessible depending on
the door bar‘s position, drill through Ø 8,5 mm, drill out 13–15 mm and a depth of 35 mm
and screw (Fig. 29).
PV1820
Fixing set with all-through screw fitting to attach the lock cases onto the door frames or on
the wall (Fig. 28).
It is used if the lock cases cannot be mounted to the door frames or wall in a stable
manner. The outer cover is visible, use one
PV1820
per lock case.
Drill through the mounting holes of the lock cases with Ø 8–9 mm, drill out Ø 13–15 mm and
a depth of 35–40 mm from outside and screw the lock case (Fig. 28).
Fig. 28
Fig. 29
35
–80 mm