background image

 

 

ABUS TECHNOLOGIES INC.

 

 

 

PT

 

 

WARNING 

 
 

v

 

This manual should be passed on to the end user. 

v

 

The contents of this manual are subject to change without prior notice. 

v

 

All rights reserved.  

v

 

ABUS gives no warranty of any kind with regard to this manual, including, but not limited to, fitness for a 

particular purpose. 

v

 

If any question arises or errors are found, or if any information is missing from this manual, please inform 

your supplier or inform at 

info@abustek.com

v

 

The specifications mentioned in this manual are limited to those for the standard type under the specified 

model number break-down and do not necessarily apply for customized instruments. 

v

 

Please note that changes in  the specifications, construction, or component parts of the instrument may 

not immediately be reflected in this manual at the time of change. 

v

 

If the customer or any third party is harmed by the use of this product, ABUS assumes no responsibility 

for any  such harm owing  to  any  defects  in  the  product  which  were  not  predictable,  or for  any  indirect 

damages. 

 
Although  Warning hazards  are  related  to personal  injury,  and  Caution  hazards are associated  with 

equipment  or  property  damage,  it  must  be  understood  that  operation  of  damaged  equipment  could,  under 
certain  operational conditions, result  in  degraded process system performance  leading  to personal  injury  or 
death. Therefore, comply fully with all Warning and Caution notices.  

Information  in  this  manual  is  intended  only  to  assist  our  customers  in  the  efficient  operation  of our 

equipment. Use of this manual for any other purpose is specifically prohibited and its contents are not to be 
reproduced  in  full  or  part  without  prior  approval  of  Technical  Communications  Department,  ABUS 
Technologies  
 

HEALTH AND SAFETY 

 

To ensure that our products are safe and without risk to health, the following points must be noted: 

1.  The relevant sections of these instructions must be read carefully before proceeding. 
2.  Warning labels on containers and packages must be observed. 
3.  Installation, operation, maintenance and servicing must only be carried out by suitably trained personnel 

and  in  accordance  with  the  information  given.  Any  deviation  from  these  instructions  will  transfer  the 
complete liability to the user. 

4.  Normal safety precautions must be taken to avoid the possibility of an accident occurring when operating 

in conditions of high pressure and/or temperature. 

5.  Chemicals must be stored away from heat, protected from temperature extremes and powders kept dry. 

Normal safe handling procedures must be used. 

6.  When disposing of chemicals ensure that no two chemicals are mixed. 
Safety advice concerning the use of the equipment described in this manual or any relevant hazard data 
sheets (where applicable) may be obtained from the Company address on the back cover, together with 
servicing and spares information.

 

 

Summary of Contents for PT Series

Page 1: ...PT Series Pressure Transmitters User Manual ABUS TECHNOLOGIES INC ...

Page 2: ... to personal injury or death Therefore comply fully with all Warning and Caution notices Information in this manual is intended only to assist our customers in the efficient operation of our equipment Use of this manual for any other purpose is specifically prohibited and its contents are not to be reproduced in full or part without prior approval of Technical Communications Department ABUS Techno...

Page 3: ... 1 Features 2 Technical Parameters 4 4 5 3 Dimensions 5 4 Ordering Details 6 5 Connections Output Characteristics 7 8 6 Installation Recommendation 9 7 7 Operation 1 Zero and Span Adjustment Procedure 2 Example for Usage 9 9 10 8 Maintenance Troubleshooting 10 10 9 Safety Precautions 11 10 Warranty 11 ...

Page 4: ...There are no internal soft sealing materials that may react with the media or deteriorate over time The compact case is also made of stainless steel and is available with environmental protection ratings PT Series industrial Pressure transmitter adopts high performance chips and deals with special amplified chip integrative configuration and smart profile They are widely used in field of hydraulic...

Page 5: ...re 1 5 x F S Adjustability Zero Span 10 using potentiometers inside Electrical Connections M12 connector Five Pin bendix connector Hirschman Type or Direct down lead Process Connection G1 4 M20 x 1 5 1 4NPT Customized On request Pressure Inlet All media compatible with stainless steel 316 Operating temperature 40 85 C 125 C for short durations Higher range on request Ambient temperature 20 80 C We...

Page 6: ...p Powered Indicator 0 W O Indicator Zero and Span Adjustment 1 With Internal Z S 0 W O Example PT20 10 D 1 W LPI PT 1 STANDARD RANGES FOR PT SERIES CODE GAUGE ABS PRESSURE CODE COMPOUND 01 1 00 bar 17 600 00 bar 02 1 60 bar 18 1000 00 bar 03 2 50 bar 19 1500 00 Bar 04 4 00 bar 20 1800 00 Bar 05 6 00 bar 06 10 00 bar COMPOUND 07 16 00 bar 41 1 0 6 bar 08 20 00 bar 42 1 1 0 bar 09 25 00 bar 43 1 2 0...

Page 7: ...ABUS TECHNOLOGIES INC 7 PT 5 CONNECTIONS WIRE SIGNAL OUTPUT EXCITATION 2 wire 4 20mA 12 36 Vdc 3 wire 0 10 Vdc 12 18 Vdc ...

Page 8: ...ABUS TECHNOLOGIES INC 8 PT Output Characteristics FOR PT20 12XXXX Pressure Transmitter C D A B C D ...

Page 9: ...Four Terminals will be found on top of which will be a rubber washer Remove the rubber washer gently 3 This next step is crucial and to be done very gently Holding the PT in the palm of the hand press down the four terminals and revolve the thread such that the terminals do not move at all This is necessary as the wiring inside the casing might get twisted and the device will be damaged 4 After th...

Page 10: ...tput Check the wiring configuration Check the input power supply 2 No variation in output Check for leakage at pressure port point Check the span set of Indicating Instrument 3 Pressure not holding at constant input pressure Check for leakage pressure point Check for the connections ensure they are properly tightened ...

Page 11: ...g 10 WARRANTY ABUS provides the original purchaser of this instrument a one 1 year warranty against defects in material and workmanship under the following terms The one year warranty begins on the day of shipment as stated on the sales bill During the warranty period all costs of material and labor will be free of charge provided that the instrument does not show any evidence of misuse For mainte...

Reviews: