background image

 

 

ABUS TECHNOLOGIES INC.

 

 

 

PT

 

 

 

4.  ORDERING DETAILS 

 

TYPE 

DESCRIPTION 

Type 

PT10 

Absolute Pressure Transmitter 

0 ~ 25 bar 

PT20 

Gauge/Compound Pressure Transmitter 

-1 ~ 0 ~ 1800 bar 

PT30 

Vacuum Pressure Transmitter 

-760 ~ 0 mmHG 

Range 

 

__ 

 

Specify Range code 

Output 

 

 

4 ~ 20 mA 

0 ~ 10 V 

Others, specify 

Process 

Connection 

 

 

G 1/4” 

G 1/2” 

1/4” NPT 

Others, specify 

Electrical 

Connection 

 

 

DIN Connector (Hirschman Type) 

Thread Screw 

Bendix Connector 

Direct Down-lead 

Integral 

Indicator (Refer 

LPI-PT) 

 

+ LPI-PT 

 

Loop Powered Indicator 

W/O Indicator 

Zero and Span 

Adjustment 

 

 

With Internal Z & S 

W/O 

Example: PT20 >10 > D > 1 > W > LPI-PT > 1 

STANDARD RANGES FOR PT SERIES 

CODE 

GAUGE/ABS. PRESSURE 

CODE 

COMPOUND 

01 

1.00 bar 

17 

600.00 bar 

02 

1.60 bar 

18 

1000.00 bar 

03 

2.50 bar 

19 

1500.00 Bar 

04 

4.00 bar 

20 

1800.00 Bar 

05 

6.00 bar 

 

 

06 

10.00 bar 

 

COMPOUND 

07 

16.00 bar 

41 

-1 ~ 0.6 bar 

08 

20.00 bar 

42 

-1 ~ 1.0 bar 

09 

25.00 bar 

43 

-1 ~ 2.0 bar 

10 

40.00 bar 

44 

-1 ~ 3.0 bar 

11 

60.00 bar 

45 

-1 ~ 5.0 bar 

12 

100.00 bar 

46 

-1 ~ 9.0 bar 

13 

160.00 bar 

 

 

14 

200.00 bar 

 

VACUUM 

15 

250.00 bar 

61 

-760 ~ 0 mm/Hg 

16 

400.00 bar 

 

 

CUSTOMIZED RANGES & UNITS - MARK 00 AS THE CODE, SPECIFY 

RANGE AND UNIT AT THE END OF PART NO. 

Example: PT20 >00 > D > 1 > W >0 > 0 >0-50 PSI

  

Table 1 

Summary of Contents for PT Series

Page 1: ...PT Series Pressure Transmitters User Manual ABUS TECHNOLOGIES INC ...

Page 2: ... to personal injury or death Therefore comply fully with all Warning and Caution notices Information in this manual is intended only to assist our customers in the efficient operation of our equipment Use of this manual for any other purpose is specifically prohibited and its contents are not to be reproduced in full or part without prior approval of Technical Communications Department ABUS Techno...

Page 3: ... 1 Features 2 Technical Parameters 4 4 5 3 Dimensions 5 4 Ordering Details 6 5 Connections Output Characteristics 7 8 6 Installation Recommendation 9 7 7 Operation 1 Zero and Span Adjustment Procedure 2 Example for Usage 9 9 10 8 Maintenance Troubleshooting 10 10 9 Safety Precautions 11 10 Warranty 11 ...

Page 4: ...There are no internal soft sealing materials that may react with the media or deteriorate over time The compact case is also made of stainless steel and is available with environmental protection ratings PT Series industrial Pressure transmitter adopts high performance chips and deals with special amplified chip integrative configuration and smart profile They are widely used in field of hydraulic...

Page 5: ...re 1 5 x F S Adjustability Zero Span 10 using potentiometers inside Electrical Connections M12 connector Five Pin bendix connector Hirschman Type or Direct down lead Process Connection G1 4 M20 x 1 5 1 4NPT Customized On request Pressure Inlet All media compatible with stainless steel 316 Operating temperature 40 85 C 125 C for short durations Higher range on request Ambient temperature 20 80 C We...

Page 6: ...p Powered Indicator 0 W O Indicator Zero and Span Adjustment 1 With Internal Z S 0 W O Example PT20 10 D 1 W LPI PT 1 STANDARD RANGES FOR PT SERIES CODE GAUGE ABS PRESSURE CODE COMPOUND 01 1 00 bar 17 600 00 bar 02 1 60 bar 18 1000 00 bar 03 2 50 bar 19 1500 00 Bar 04 4 00 bar 20 1800 00 Bar 05 6 00 bar 06 10 00 bar COMPOUND 07 16 00 bar 41 1 0 6 bar 08 20 00 bar 42 1 1 0 bar 09 25 00 bar 43 1 2 0...

Page 7: ...ABUS TECHNOLOGIES INC 7 PT 5 CONNECTIONS WIRE SIGNAL OUTPUT EXCITATION 2 wire 4 20mA 12 36 Vdc 3 wire 0 10 Vdc 12 18 Vdc ...

Page 8: ...ABUS TECHNOLOGIES INC 8 PT Output Characteristics FOR PT20 12XXXX Pressure Transmitter C D A B C D ...

Page 9: ...Four Terminals will be found on top of which will be a rubber washer Remove the rubber washer gently 3 This next step is crucial and to be done very gently Holding the PT in the palm of the hand press down the four terminals and revolve the thread such that the terminals do not move at all This is necessary as the wiring inside the casing might get twisted and the device will be damaged 4 After th...

Page 10: ...tput Check the wiring configuration Check the input power supply 2 No variation in output Check for leakage at pressure port point Check the span set of Indicating Instrument 3 Pressure not holding at constant input pressure Check for leakage pressure point Check for the connections ensure they are properly tightened ...

Page 11: ...g 10 WARRANTY ABUS provides the original purchaser of this instrument a one 1 year warranty against defects in material and workmanship under the following terms The one year warranty begins on the day of shipment as stated on the sales bill During the warranty period all costs of material and labor will be free of charge provided that the instrument does not show any evidence of misuse For mainte...

Reviews: