3. Advanced Z-Wave Parameter
3.1. Association Group Information
Z-Wave devices can control other devices directly. This direct control is called in Z-Wave association.
For this purpose, the device ID of the device to be controlled must be stored in the controlling devices.
This is done in so-called association groups. An association group is always linked to an event in the
controlling device (pressing a key or triggering a sensor). When this event occurs, a control command
- usually a BASIC SET - is sent to all devices stored in an association group
.
The device supports the following association group:
Group
Number
Maximum
Devices
Transmitted Content
Group 1
1
(0x01)
Z-Wave Plus Lifeline
3.2. Overview Configuration Parameter
Z-Wave products can be used in the network immediately after inclusion. Through configuration
settings, however, the behaviour of the device can be adapted even better to the requirements of the
application and additional functions can be activated.
Para-
meter
Byte-
size
Funktion
Default-Value
(Decimal)
Description
1
1
Temperature of
NTC
-
This parameter can only be read and not set.
255
4
Reset
-
This parameter cannot been read, but only set
▪
2290649224 = Reset to factory
configuration and removed the Z-Wave
network.
▪
2281701376 = Reset Configuration
parameter to default value.
(Hexadezimal: 0x88888888 / 0x88000000)
3.3. Command Classes
1. Association Group Information V1
2. Association V2
3. Basic V1
4. Color Switch V1
5. Configuration V1
6. Device Reset Local V1
7. Firmware Update MD V2
8. Manufacturer Specific V2
9. Multilevel Switch V2
10. Power level
11. Security V1
12. Switch All V1
13. Version V2
14. Z-Wave Plus Info V2