81
9.2 RS-485 Termination
The 1
st
DIP of SW2 is used for 100
termination.
Set on 1
st
DIP of SW2 only by the last connected camera from the loop (CAM n).
Even in case of only one camera, set ON 1
st
-DIP of SW2.
9.3 Protocol
The 3
rd
, 4
TH
of DIP SW2 above are used for Protocol Setting.
Factory Default: Pelco-D or Pelco-P (Auto detection)
DIP SW2 - 3
rd
4
th
OFF / OFF
Pelco-D or Pelco-P
ON / ON
Maxpro protocol
9.4 Baud Rate Setting
The 7
th
, 8
th
SW of DIP SW2 is used for baud rate setting.
With DIP SW2 baud rate can be changed to 4800bps, 9600bps.
Factory Default: 2400bps.
DIP SW2-7
th
DIP
SW2-8
th
BAUD
RATE
OFF OFF
Not
Used
OFF ON 2400bps
ON OFF
4800bps
ON ON
9600bps
* The 2
nd
, 5
th
, 6
th
of DIP SW2 are not used.