Configuration
32
Dwell Time
Select the dwell time for switching the
alarm output.
Activate the alarm output by ticking the "Settings"
box.
Define the schedule for the recorder alarm output in
the event of an alarm under
"Settings"
.
Click on
Copy
to apply these settings to other cam-
eras.
Confirm the settings by clicking on
Apply
and exit the
menu by clicking on
Back
.
RS-232
Parameter
Setting
Baud Rate
Set the transmission speed
you require using the baud
rate
Data Bit
Set the data size to be trans-
mitted
Stop Bit
Set the stop bit value for
data transmission
Parity
Set the parity to test the er-
ror-free transmission of data
packages
Flow Ctrl
Required to transfer data to
the Speed Dome without the
data transmission being per-
formed too quickly and data
packages being lost
Use
Select your usage type
–
"Console" (only for service
purposes) or "Transparent
Channel" (for virtual RS-485
control)
Exception
Set the response of the recorder for warning messages
and system events here. To do this, activate the "Enable
Event Hint" setting.
You can trigger a warning for the following error types:
HDD Full
HDD Error
Network Disconnected
IP Conflicted
Illegal Login
Exception Error
Parameter
Notifications
Audible Warning
The device emits a repeated
signal tone.
Notify Surveillance Cen-
ter
A notification is sent to the
CMS software event log.
Send Email
An email is sent to a speci-
fied email address.
Trigger Alarm Output
The selected alarm output is
switched in the event of a
fault.