27
PROGRAMMING
TRANSITION TEMPERATURE SETTING
Adjusts the transition threshold between the fan
speeds in the AUTO Mode temperature triggers.
Press the up or down button to cycle through 0°F
to 8°F (0°C to 4°C) and set a transition threshold.
The fan speed will be set one level above the
OFF Mode speed when the sensor temperature
first meets or exceeds the high temperature
trigger. For every transition threshold crossed,
the fan speed will ramp up by one speed level,
up until it reaches the speed set in ON Mode.
In this example, your high temperature trigger is
set at 80°F, the OFF Mode speed is 0, and the
ON Mode speed is 6. If the transition threshold
is set to 0°F, then the fan will trigger to run at
speed 6 when the sensor temperature meets
or exceeds 80°F. However, if the transition
threshold is set to 2°F, then the fan will trigger to
run at speed 1 when it meets or exceeds 80°F.
It will then step up to speed 2 when meeting or
exceeding 82°F, speed 3 at 84°F, speed 4 at
86°F, and speed 5 at 88°F. From 90°F on, it will
run at speed 6, the speed set in ON Mode.