26
BUFFER TEMPERATURE SETTING
The buffer that used in auto mode temperature
trigger can be adjusted to prevent the device from
turning on and off too quickly due to variations in the
environment.
For high temperature triggers, once your device is on,
it will only turn off when the measured temperature
falls below the set temperature by the buffer number
you have set here.
For low temperature triggers, once your device is on,
it will only turn off when the measured temperature
rises above the set temperature by the buffer number
you have set here.
PROGRAMMING
PM
T°
BUFF.
BUFFER HUMIDITY SETTING
The buffer that used in auto mode humidity trigger
can be adjusted to prevent the device from turning
on and off too quickly due to variations in the
environment.
For high humidity triggers, once your device is on, it
will only turn off when the measured humidity falls
below the set humidity by the buffer number you have
set here.
For low humidity triggers, once your device is on, it
will only turn off when the measured humidity rises
above the set humidity by the buffer number you
have set here.
PM
H%
%
BUFF.