Ʋƴ
No.
Malfunction
Name
Display Method of Indoor Unit
Display Method of Outdoor
Unit
A/C
Status
Possible
Causes
Dual 8
Code
Display
Indicator Display (during
blinking, ON 0.5s and OFF
0.5s)
Indicator has 3 kinds of display
status and during blinking, ON
0.5s and OFF 0.5s
Oper-
ation
Indicator
Cool
Indica-
tor
Heat-
ing
Indica-
tor
Yellow
Indica-
tor
Red
Indica-
tor
Green
Indicator
26
Compressor
intermediate
frequence in test
state
P3
(during
blinking,
ON
0.25s
and
OFF
0.25s)
(during
blink-
ing,
ON
0.25s
and
OFF
0.25s)
Showing during middle cooling or
middle heating test
27
Overcurrent
protection of
phase
current for
compressor
P5
OFF 3S
and
blink
15
times
During cooling and drying
operation, compressor will stop
while indoor fan will operate;
During heating operation, the
complete unit will stop
operation.
Refer to the malfunction
analysis (IPM protection, loss
of synchronism protection and
overcurrent protection of phase
current for compressor.
28
Charging
malfunction
of capacitor
PU
OFF 3S
and
blink
17
times
During cooling and drying
operation, compressor will stop
while indoor fan will operate;
During heating operation, the
complete unit will stop
Refer to the part three—charging
malfunction analysis of capacitor
29
Malfunction
of module
temperature
sensor circuit
P7
OFF 3S
and
blink
18
times
During cooling and drying
operation, compressor will stop
while indoor fan will operate;
During heating operation, the
complete unit will stop
Replace outdoor control panel
AP1
30
Module high
temperature
protection
P8
OFF 3S
and
blink
19
times
During cooling operation,
compressor will stop while
indoor fan will operate;
During heating operation, the
complete unit will stop
After the complete unit de-ener-
gized for 20mins, check whether
the thermal grease on IPM
Module of outdoor conrol panel
AP1 is sufficient and whether
the radiator is inserted tightly. If
its no use, please replace control
panel AP1.
31
Decrease
frequency
due to high
temperature
resistant
during
heating
operation
H0
OFF 3S
and
blink
10
times
All loads operate normally,
while
operation frequency for
compressor is decreased
Refer to the malfunction analysis
(overload, high temperature
resistant)
32
Static
dedusting
protection
H2
OFF 3S
and
blink
twice
33
Overload
protection for
compressor
H3
OFF 3S
and
blink
3 times
OFF 1S
and
blink
8 times
During cooling and drying
operation, compressor will stop
while indoor fan will operate;
During heating operation, the
complete unit will stop
operation.
1. Wiring terminal OVC-COMP
is loosened. In normal state, the
resistance for this terminal should
be less than 1ohm.
2.Refer to the malfunction
analysis (
discharge protection, overload)