Ƶƶ
Steps
Procedure
12. Remove Water Tray
Pullthe water tray upwards, and then
remove the water tray.
13. Remove connection pipe between indoor and
outdoor units
Seperate the connection pipe between
indoor and outdoor units.
14. Remove pipe-stopping plate
Remove two scews on pipe-stopping
plate for indoor unit, and then remove the
pipe-stopping plate.
15. Remove damping board
Remove 2 screws on damping board, and
then remove the damping board.
water tray
connection position for indoor and outdoor units' connection pipe
pipe-stopping plate
screw
screw
damping board