background image

Burr Zero Point

The point where the burrs can no longer be adjusted finer. When turning the adjustment 

dial finer, it will encounter total resistance and will not be able to turn.

DO NOT

 attempt to turn on the grinder when burrs are at zero as damage may occur. 

Note that the “0” on the grind adjustment ring does not equal the Burr Zero Point for your 

Orbit.

Burr Touch Point

The point where the burrs make initial contact with each other, and make an audible 

sound of metal-on-metal scraping. This is the finest possible grind setting. If performing 

a burr alignment or installing new burrs, the burr touch point may change position. Orbit 

users are advised that attempting to grind finer than the burr touch point may result in 

damage to the burrs or motor. 

Stepless Adjustment

Orbit’s setting dial has a 0.75 mm thread pitch that allows smooth and continuous 

adjustment from espresso to filter coffee in just one rotation. That gives plenty of room 

to fine-tune your shots, as well as swap from small pour over brews to large batches 

whenever you need to.

Auto-stop

The Orbit will automatically stop grinding once the bean chamber is empty after 3 

seconds. If the Orbit is turned on without any beans in it, the grinder will automatically stop 

after 15 seconds.

You can adjust the auto-stop setting through the Orbit App for continuous grinding. Once 

the auto-stop setting is turned off, the grinder will continue grinding until it is manually 

stopped by the Orbit button.

 

10

Summary of Contents for AOT002

Page 1: ...Acaia Orbit User Manual FW 1 0 6 AOT002 AOT003...

Page 2: ...ustment Auto stop Auto purge Stall Prevention Advanced Control with the Orbit App App Overview When Connected to the Orbit When Connected with Orbit and Lunar RPM Profile Overview Time based Grinding...

Page 3: ...he built in auto reverse cleaning process and a knocker grind retention for single dosing is kept at a minimum The companion Orbit app gives you full control of the Orbit You can personalize the butto...

Page 4: ...s appliance can be used by children aged from 8 years and above and people with reduced physical sensory mental capabilities or lack of experience and knowledge if they are under supervision or have b...

Page 5: ...er spring Spout Spout springs m3x8mm screw i head black Support bracket m3x5mm screw i head black LED cover LED m3x8mm screw flat head Support pillar Description Power sponge Power supply Power bracke...

Page 6: ...In The Box 6 Orbit Coffee Grinder 58 mm Portafilter Dosing Cup with Magnetic Pad Power Cable Spout Extender Optional Lunar Magnetic Strips Application Tool Lunar Magnetic Strips Hex Wrench...

Page 7: ...osing Cup on the base of the Orbit Turn on the main power switch at the back Click the Orbit button in the front When the button light is on you are ready to go Note Acaia tests every unit with coffee...

Page 8: ...ite Blue Cyan Magenta Red Green Yellow Orange Preset A 600 RPM Preset B 1000 RPM Preset C 1500 RPM Manual Mode Warning Firmware update Reset to factory default Purge Cleaning in progress Connecting in...

Page 9: ...g Speed Press and hold the Orbit button to switch between 3 default RPM profiles The 3 presets are each represented by a different color light You can access the RPM profiling feature through the Orbi...

Page 10: ...users are advised that attempting to grind finer than the burr touch point may result in damage to the burrs or motor Stepless Adjustment Orbit s setting dial has a 0 75 mm thread pitch that allows s...

Page 11: ...each grind Stall Prevention When grinding if the Orbit burrs stall and stop grinding it will automatically stop the motor The button will flash red to notify the user that a stall has occurred and th...

Page 12: ...e Magenta light Purge Button RPM Profile Settings Settings Sharing Function Will display a white dot when in connection Orbit Connection Icon Lunar Connection Icon 12 The companion Orbit App gives you...

Page 13: ...Orbit Only viewable when Lunar is connected to Orbit Only usable when Lunar is connected to Orbit Grinding time Grinding time Real Time RPM Real Time RPM Real Time Weight When Connected to the Orbit W...

Page 14: ...he stages can be set between 600 1500 RPM and also include a timer to set how long each stage should run RPM profiling is only available while the Orbit is connected to the Orbit app The modified sett...

Page 15: ...or each grinding session The grinder will automatically stop when the target time is reached With RPM profiling enabled change the initial and ending phase time to limit the grinding length of one ses...

Page 16: ...line in the graph below 1 2 3 Manual Grinding Orbit s manual grinding mode enables you to control the RPM freely in real time During a single grinding session you can change the speed of the grinder...

Page 17: ...tions customizable Double Click Triple Click Press and Hold for 10 seconds The customizable options are Pulse Purge Power Off and Reverse Burr Setting Please note that the action Click is set to power...

Page 18: ...tting is on 2 On Auto Purge enabled 3 Off Auto Purge disabled 4 Auto Purge is only supported in single dose grinding Auto Off 1 The default setting is ON 2 On Auto Off enabled Orbit automatically ente...

Page 19: ...nction to give you a hands free operating experience See the instructions in the next section on how to pair your Lunar to Orbit and how the Lunar functions when connected to the grinder Auto Grinding...

Page 20: ...ic strips application tool along the dotted line Peel off the backing paper of the magnetic strips Fold the flaps at the top and bottom of the application tool along the dotted line Align the magnetic...

Page 21: ...ia Updater App Place the Lunar on the Orbit When the Orbit button turns orange and the Lunar displays Confirm tap on the Lunar to confirm pairing Check if the Lunar has the magnetic strips aligned cor...

Page 22: ...ode Grind Pause Pulse Increase value Reset grind by weight session Adjust target weight and RPM Toggle auto start grinding 3 seconds Click Double Click Press and Hold Bluetooth Connection Indicator Po...

Page 23: ...ed When the target weight is reached the Orbit will automatically stop the motor Adjusting Weight and RPM in Grind by weight Mode 23 To adjust the target weight and RPM press and hold until the weight...

Page 24: ...These screws can be replaced with thumb screws for easy assembly 5 Attach the spout extender 24 Care and Cleaning Do not immerse the Orbit in water Use a soft cloth with warm water only to clean the...

Page 25: ...dosing cup magnet affect scale readings A The dosing cup magnet can affect the readings but this does not impact the weighing after you perform a tare The weight result will remain accurate and consis...

Page 26: ...ill be reset to factory default You can also reset the Orbit to factory default with the Orbit APP To enter the Orbit firmware update mode press and hold the Orbit button in the front while the Orbit...

Page 27: ...Operating Ambient Temperature 0 40c RPM Profile 600 1500 Adjustable RPM Profile Duty Cycle Recommended duty cycle for Orbit is 60s running time with a rest time of 30s Connectivity Bluetooth 5 0 Warra...

Page 28: ...l rights reserved No part of this manual may be reproduced processed duplicated or published in any form by photocopying microfilming reprinting or any other method in particular electronic means with...