background image

Make sure to 

remove

 the 

spout extender from the 

Orbit spout and 

place

 the 

dosing cup on the Lunar.

At the end of each 

session, you can click the 

Orbit button to pulse a 

small amount of coffee if 

needed.

Remove

 the dosing cup 

or 

double tap

      to reset 

the current grind-by-

weight session.

To begin the grinding 

session, 

click

 the Orbit 

button. The Orbit will start 

grinding until the target 

weight is reached.

When the target weight 

is reached, the Orbit will 

automatically stop the 

motor.

Adjusting Weight and RPM in Grind-by-weight Mode

23

To adjust the target weight 

and RPM, 

press and hold

     

      until the weight starts 

blinking.

When you reach the 

desired target weight, 

wait 

5 seconds

 to move on to 

the RPM adjustment.

When the weight starts 

blinking, 

tap

      to increase 

and 

tap

      to decrease.

When adjusting target 

weight and RPM, 

press and 

hold

      /      to speed up 

the adjustment.

When the RPM starts 

blinking, 

tap

      to increase 

and 

tap

      to decrease.

When you reach the 

desired RPM, 

wait 5 

seconds

 to save.

1

4

7

10

11

2

5

8

3

6

9

Summary of Contents for AOT002

Page 1: ...Acaia Orbit User Manual FW 1 0 6 AOT002 AOT003...

Page 2: ...ustment Auto stop Auto purge Stall Prevention Advanced Control with the Orbit App App Overview When Connected to the Orbit When Connected with Orbit and Lunar RPM Profile Overview Time based Grinding...

Page 3: ...he built in auto reverse cleaning process and a knocker grind retention for single dosing is kept at a minimum The companion Orbit app gives you full control of the Orbit You can personalize the butto...

Page 4: ...s appliance can be used by children aged from 8 years and above and people with reduced physical sensory mental capabilities or lack of experience and knowledge if they are under supervision or have b...

Page 5: ...er spring Spout Spout springs m3x8mm screw i head black Support bracket m3x5mm screw i head black LED cover LED m3x8mm screw flat head Support pillar Description Power sponge Power supply Power bracke...

Page 6: ...In The Box 6 Orbit Coffee Grinder 58 mm Portafilter Dosing Cup with Magnetic Pad Power Cable Spout Extender Optional Lunar Magnetic Strips Application Tool Lunar Magnetic Strips Hex Wrench...

Page 7: ...osing Cup on the base of the Orbit Turn on the main power switch at the back Click the Orbit button in the front When the button light is on you are ready to go Note Acaia tests every unit with coffee...

Page 8: ...ite Blue Cyan Magenta Red Green Yellow Orange Preset A 600 RPM Preset B 1000 RPM Preset C 1500 RPM Manual Mode Warning Firmware update Reset to factory default Purge Cleaning in progress Connecting in...

Page 9: ...g Speed Press and hold the Orbit button to switch between 3 default RPM profiles The 3 presets are each represented by a different color light You can access the RPM profiling feature through the Orbi...

Page 10: ...users are advised that attempting to grind finer than the burr touch point may result in damage to the burrs or motor Stepless Adjustment Orbit s setting dial has a 0 75 mm thread pitch that allows s...

Page 11: ...each grind Stall Prevention When grinding if the Orbit burrs stall and stop grinding it will automatically stop the motor The button will flash red to notify the user that a stall has occurred and th...

Page 12: ...e Magenta light Purge Button RPM Profile Settings Settings Sharing Function Will display a white dot when in connection Orbit Connection Icon Lunar Connection Icon 12 The companion Orbit App gives you...

Page 13: ...Orbit Only viewable when Lunar is connected to Orbit Only usable when Lunar is connected to Orbit Grinding time Grinding time Real Time RPM Real Time RPM Real Time Weight When Connected to the Orbit W...

Page 14: ...he stages can be set between 600 1500 RPM and also include a timer to set how long each stage should run RPM profiling is only available while the Orbit is connected to the Orbit app The modified sett...

Page 15: ...or each grinding session The grinder will automatically stop when the target time is reached With RPM profiling enabled change the initial and ending phase time to limit the grinding length of one ses...

Page 16: ...line in the graph below 1 2 3 Manual Grinding Orbit s manual grinding mode enables you to control the RPM freely in real time During a single grinding session you can change the speed of the grinder...

Page 17: ...tions customizable Double Click Triple Click Press and Hold for 10 seconds The customizable options are Pulse Purge Power Off and Reverse Burr Setting Please note that the action Click is set to power...

Page 18: ...tting is on 2 On Auto Purge enabled 3 Off Auto Purge disabled 4 Auto Purge is only supported in single dose grinding Auto Off 1 The default setting is ON 2 On Auto Off enabled Orbit automatically ente...

Page 19: ...nction to give you a hands free operating experience See the instructions in the next section on how to pair your Lunar to Orbit and how the Lunar functions when connected to the grinder Auto Grinding...

Page 20: ...ic strips application tool along the dotted line Peel off the backing paper of the magnetic strips Fold the flaps at the top and bottom of the application tool along the dotted line Align the magnetic...

Page 21: ...ia Updater App Place the Lunar on the Orbit When the Orbit button turns orange and the Lunar displays Confirm tap on the Lunar to confirm pairing Check if the Lunar has the magnetic strips aligned cor...

Page 22: ...ode Grind Pause Pulse Increase value Reset grind by weight session Adjust target weight and RPM Toggle auto start grinding 3 seconds Click Double Click Press and Hold Bluetooth Connection Indicator Po...

Page 23: ...ed When the target weight is reached the Orbit will automatically stop the motor Adjusting Weight and RPM in Grind by weight Mode 23 To adjust the target weight and RPM press and hold until the weight...

Page 24: ...These screws can be replaced with thumb screws for easy assembly 5 Attach the spout extender 24 Care and Cleaning Do not immerse the Orbit in water Use a soft cloth with warm water only to clean the...

Page 25: ...dosing cup magnet affect scale readings A The dosing cup magnet can affect the readings but this does not impact the weighing after you perform a tare The weight result will remain accurate and consis...

Page 26: ...ill be reset to factory default You can also reset the Orbit to factory default with the Orbit APP To enter the Orbit firmware update mode press and hold the Orbit button in the front while the Orbit...

Page 27: ...Operating Ambient Temperature 0 40c RPM Profile 600 1500 Adjustable RPM Profile Duty Cycle Recommended duty cycle for Orbit is 60s running time with a rest time of 30s Connectivity Bluetooth 5 0 Warra...