background image

Mode 3 -Timer Starts with Flow Mode

Place an item on the scale. Tap the power button to automatically tare and prepare the timer to 

detect the flow of water. The timer will flash, indicating that it is ready. Begin pouring and the 

timer will start with flow detection from the pour. The timer stops when the brewing equipment is 

removed.

Display

The LED display shows [0:00 0] with the timer on the left and the weight on the right in gram 

units.

The LED display shows [0:00 0.00] with the timer on the left and the weight on the right in 

ounce units.

The timer displays from [0:00] to [9:59] and then the timer will stop.

Chapter 3: Basics                                                                                                                                       15

0

0

.

00

.

Action

Operation

Initiate Auto Start

Tap power button

Tare

Tap tare button

Stop Timer

While timer is running. Tap power button

Reset Mode

Double tap tare button

Switch Mode

Long press power button

Summary of Contents for Pearl

Page 1: ...nstructions in this operation manual apply to the Acaia Pearl Coffee Scale You have purchased a quality precision weighing scale that requires handling with care Make sure to read through this operation manual prior to using the scale Acaia Pearl Operation Manual ...

Page 2: ...he standard masses to which it has been compared For more details please read the Calibration Mode section in the operation manual CAUTION 1 Do not place any hot objects directly on the weighing pan Please use a heat resistant pad under hot objects 2 Any modification made without the consent of the manufacturer may result in damage to scale ...

Page 3: ...Mode 16 Mode 4 Beverage Mode 17 Mode 5 Auto Tare Mode 18 Chapter 4 Configuration 18 Accessing the Pearl s Settings 19 Diagram of the Settings Menu 20 Sleep Timer Setting 20 Auto Zero 20 Zero Tracking Setting 21 Key Sound Setting 21 Zero Range Setting 21 Weighing Filter Setting 22 Default Weighing Unit 22 Weighing Resolution 22 Espresso Mode Setting 22 Dual Display Mode Setting 23 Timer Starts with...

Page 4: ...er information Warning Incorrect handling of this product could possibly result in personal injury or physical damage Specifications Aprox Weight 462 g Capacity 2000 g 70 54 oz Measuring Units g oz Weighing Range 1 Maximum capacity 1000 0 g 35 280 oz Minimum capacity 1 0 g 0 035 oz Division 0 1 g 0 005 oz Weighing Range 2 Maximum capacity 2000 0 g 70 540 oz Minimum capacity 1000 0 g 35 280 oz Divi...

Page 5: ...rview Note For the best performance place the weight in the center of the weighing platform Chapter 1 Scale at a Glance 5 Weighing Pan Power Button LED Display Micro B USB Port Tare Button Scale Front Scale Back ...

Page 6: ...y Mode from Settings Menu Tare Button Tare While in Weighing Mode tap to perform tare operation Toggle units Long press to changing between Gram and Ounce in Weighing Only Mode Toggle settings option While editing a setting tap to scroll through its options Reset mode Double tap to reset a mode This zeros the weight and sets the timer to 0 00 Confirm While editing a setting press and hold for 2 se...

Page 7: ...espresso mode the timer displays from 0 to 59 seconds and will reset when reaching 60 seconds The orange LED indicator on the lower left turns on when the timer resets Tare Operation The green tare indicator on the lower right turns on when the tare button is pressed Ounce Indication The green ounce indicator on the upper right turns on when the weighing unit is in ounces Chapter 1 Scale at a Glan...

Page 8: ...ully charge the battery from empty Try not to let the battery completely run out but be sure to only charge the scale around once a week as needed A fully charged battery can continuously last for about 25 hours Battery percentage can be viewed via the Acaia Apps Please note Using a fast charging charging block or charging hub a charging block hub delivering over 5v at 1A could damage your Acaia s...

Page 9: ...ble vibration free and if possible a horizontal location for the weighing platform Do not locate the scale near any equipment instrument which contains magnets Avoid places where room temperatures are unstable Room temperature above 40 or below 15 may result in weighing inaccuracy Chapter 2 Getting Started 9 ...

Page 10: ...USB port located on the back panel of the scale Long press power button to turn on the scale It is highly recommended to calibrate the scale with a calibration weight before using Please make sure to use a heat resistant pad under hot objects Chapter 2 Getting Started 10 ...

Page 11: ...esso Mode Mode 2 Dual Display Mode Mode 3 Timer Starts with Flow Mode Mode 4 Beverage Mode Mode 5 Auto Tare Mode Action Operation Turn On Scale Press and hold power button Turn Off Scale Double tap power button Switch Mode Press and hold power button while scale is on Tare Weight Tap tare button Reset Mode Double tap tare button Chapter 3 Basics 11 ...

Page 12: ...t will appear in the upper right of the LED display and the scale will read 0 000 when weighing in ounces The readability is 0 1 g for grams and 0 005 oz for ounces The LED display shows 0 0 when the weighing unit is in gram Action Operation Tare Weight Tap tare button Toggle Units G Oz Long press tare button Reset Mode Double tap tare button Switch Mode Long press power button Chapter 3 Basics 12...

Page 13: ...ched When it resets the mode Indicator flashes When the weight exceeds 999 grams the LED display only shows the integer part the decimal point will not be displayed The LED display shows up to in maximum 1999 g If the weight exceeds 1999 grams the scale will display _ _ _ _ Action Operation Start Stop Reset Timer Tap power button Tare Weight Tap tare button Reset Mode Double tap tare button Switch...

Page 14: ... gram units the LED display shows 0 00 0 00 The maximum display time will be 9 minutes and 59 seconds The weight display on the right side of the display measures from 0 to 999 When the value is over 1000 it will restart from 0 with mode Indicator flashing Action Operation Start Stop Reset Timer Tap power button Tare Weight Tap tare button Reset Mode Double tap tare button Switch Mode Long press p...

Page 15: ...ipment is removed Display The LED display shows 0 00 0 with the timer on the left and the weight on the right in gram units The LED display shows 0 00 0 00 with the timer on the left and the weight on the right in ounce units The timer displays from 0 00 to 9 59 and then the timer will stop Chapter 3 Basics 15 0 0 00 Action Operation Initiate Auto Start Tap power button Tare Tap tare button Stop T...

Page 16: ...bilized or the tare button is pressed the next step will show in display AFTER the process is finished and the filter is removed the display will blink and flash between the water weight and beverage weight marked with b Display Action Description CUP Put the carafe cup on the scale FLt Put the filter in your pour over dripper and place on the carafe cup COF Put the coffee in the filter Timer Flas...

Page 17: ...e Display The LED display shows Atr 0 with the timer on the left and the weight on the right in gram units The LED display shows Atr 0 00 with the timer on the left and the weight on the right in ounce units Action Operation Tare Weight Tap tare button Reset Mode Double tap tare button Switch Mode Long press power button Chapter 3 Basics 17 0 Atr ...

Page 18: ... the flashing digit to the right Repeat this step for 4 times to enter Settings It will show the first setting SLEEP Key Operations in the Settings Menu 1 Tap the tare button to scroll through the Settings Menu 2 Press and hold the tare button to enter each setting s sub menu 3 Tap the tare button to scroll through options in the individual settings sub menu 4 Press and hold the tare button to sav...

Page 19: ...nge 0 rAnGE 2 100 100 Weighing Filter Fi lt 2 4 6 8 16 32 64 128 16 Default Weighing Unit Unit Gram Ounce Gram Weighing Resolution rESoL Default High Default Espresso Mode NodE_1 On Off Off Dual Display Mode NodE_2 On Off On Timer Starts with Flow Mode NodE_3 On Off Off Beverage Mode NodE_4 On Off Off Auto Tare Mode NodE_5 On Off On Bluetooth Setup bt_SEt On Off On Chapter 4 Configuration 19 ...

Page 20: ...n or enabled the scale displays the initial weight directly even if the weight is over 50 of capacity 3 To save your selection and exit the the settings sub menu press and hold the tare button for 1 second until the next setting trAcE is shown on the LED to confirm the selected option Zero Tracking Setting trAcE 1 Zero tracking is a function to help compensate the weight readout fluctuations at ze...

Page 21: ...fore instead of tare operation zero operation would be executed in this setting whenever tare button is pressed 4 Notice The difference between zero operation and tare operation is that zero operation would simply ignore the weight and display as 0 while tare operation would deduct the weight from weighing result However zero operation does not increase the scale capacity 5 To save your selection ...

Page 22: ...ss and hold tare button for 1 second until NoDE_1 is shown on the LED to confirm the selected option 5 Note After setting Weighing Resolution to high the default display will show 0 00 0 00 with timer in Dual Display Mode and Auto Start Modes Espresso Mode Setting NoDE_1 1 The default Espresso Mode Setting is set to OFF which means this mode is disabled 2 ON The Espresso Mode is enabled 3 OFF The ...

Page 23: ...nd hold tare button for 1 second until NodE_5 is shown on LED to confirm the selected option Auto Tare Mode Setting NodE_5 1 The default Auto Tare Mode is set to ON which means this mode is enabled 2 ON The Auto Tare Mode is enabled 3 OFF The Auto Tare Mode is disabled 4 To save your selection and exit the the settings sub menu press and hold tare button for 1 second until bt_SEt is shown on LED t...

Page 24: ...LED display shows CAL and then 500 2 Place a 500 g calibration weight on the scale and wait for the scale to execute the calibration procedure 3 The LED display shows End when the calibration procedure is completed You may remove the calibration weight when completed Note Calibration weight of 100 g 1000 g 1500 g or 2000 g can also be used Chapter 5 Configuration 24 ...

Page 25: ...weight is under the minimum capacity 303 Unable to make zero point for the initial weight exceeds the limit 50 of capacity 304 Please do calibrate in a stable environment without wind or shake etc 802 Unable to tare for the weight exceeds the tare range 803 Unable to tare for the weight is unstable 900 Passcode error the default passcode is 0000 Appendix 25 ...

Page 26: ...ights reserved No part of the operation manual may be reproduced processed duplicated or published in any form by photocopying microfilming reprinting or any other method in particular electronic means without the written agreement of Acaia Acaia Cupertino CA 2018 ...