Power supply Specifications

 

 

The  following  is  the  specifications  for  rated  input  voltage  and  power  supply  capacity  for 
each product.  

 

Product 

Input Power Supply  

Current 

Consumption 

Power 

Consumption 

ETOS-100XP 

AC 100V ~ 240V Free Voltage 

(50/60Hz) 

300mA or less  

64VA 

ETOS-150XP 

300mA or less  

64VA 

ETOS-500XP 

600mA or less  

128VA 

90 ~ 130 VDC 

 

130W 

 

2.3.

 

 

Battery Specification 

 

The following is the standard for the battery information for each product. It is imperative 
to read the precautions for battery use in the front of the manual before use.  
The purpose of the battery is to save the log area and user memory data and to operate RTC. 
It is not possible to charge the pertinent battery, therefore, it is imperative to replace it 
in case of discharge.    

** For purchasing a battery, contact our sales department.  
 

2.3.1.

 

Battery Application Status and Parts by Product 

Product 

Application 

Status 

Battery 

Name 

Specification 

Nominal 

voltage / 

current 

Size (mm) 

(height x diameter) 

ETOS-100XP 

XL-050F 

Lithium 

3.6V/1.2A 

28 x 16.6 

ETOS-150XP 

XL-050F 

Lithium 

3.6V/1.2A 

28 x 16.6 

ETOS-500XP 

XL-050F 

Lithium 

3.6V/1.2A 

28 x 16.6 

 

2.3.2.

 

Precautions for Use 

(1) Do not charge, disassemble, heat, put into fire, short circuit, solder or give a shock to 

the battery.  

(2) Handling battery incorrectly may cause injury to the human body due to heat, breakage and 

so on. There is a risk of fire.  

 

2.3.3.

 

Battery Life 

(1) It is possible to use the battery for at least 2 years by using  it at room temperature 

(based on 25 degree), but battery life depends on the power failure time and temperature 
conditions.  

(2) If the battery voltage drops below 1.5V, the system flag (SysBatteryLow) and log information 

of the ETOS-RD can be used to check the battery voltage drop warning.  

(3) If a warning for low battery voltage occurs, replace the battery as soon as possible for 

operation.  

(4) If the battery voltage becomes low, regular check and replacement management is required 

because it can affect log data storage, user memory data storage, and RTC operation.  

 

** When replacing the battery, it is recommended to replace the battery within 2 hours because 

the internal supercap backup is possible only up to 2 hours.  

** Before replacing the battery, please perform user memory and log backup.  
** After purchasing, a warning occurs generally after about two years. But if the battery is 

Summary of Contents for ETOS-XP Series

Page 1: ...1 Industrial Network Server ETOS XP Series ETOS XP SERIES USER S GUIDE AC T System Co Ltd 2017 06 Revision 1 1...

Page 2: ...roduct wiring and operating environment and the risks and precautions for disposal Normal Dangers When working for communication cable keep a distance of at least 100mm away from the power supply cabl...

Page 3: ...e sure to shut off the power supply from the outside before installing or removing the module card Failure to do so may result in electric shock or damage to the product Do not directly touch the cond...

Page 4: ...s while Operating Precautions When controlling the ETOS XP series in operation read this user s manual thoroughly and check the safety Incorrect parameter setting or program change may cause breakdown...

Page 5: ...ut prior notice to improve the function of the product Revision History Revision No Date Change 1 0 2016 08 First Edition 1 1 2017 06 Revision AC T Systems Co Ltd 16 11 LS ro 91beon gil Dongan gu Anya...

Page 6: ...6 OVERVIEW CHAPTER1 This chapter introduces the functional features of ETOS XP CONTENTS 1 1 Product Overview 1 2 Main Features 1 3 Products list...

Page 7: ...er memory for communication data storage and conversion Communication frame monitor memory Monitor and variable monitor function Program function for protocol conversion among heterogeneous equipment...

Page 8: ...00XP E22 Ethernet 1port electric RS 232 2port RS 422 RS 485 2port ETOS 100XP E04 Ethernet 1port electric RS 422 RS 485 4port ETOS 100XP S40 RS 232 4port ETOS 100XP S22 RS 232 2port RS 422 RS 485 2port...

Page 9: ...NUL COVER Empty Slot cover 1 3 1 Maximum Number of Supported Ports The maximum number of serial and Ethernet ports supported by product is as follows Product 100XP 150XP 500XP Ethernet 10 100Base T X...

Page 10: ...hium Battery 2 years External lithium Battery 2 years External lithium Battery 2 years Ethernet 1 Port 2 Port 2 Port 4 Port Serial additional option 4 Port 4 Port 20 Port WatchDog Built in Built in Bu...

Page 11: ...ER2 This chapter describes general function specifications Contents 2 1 General Specification 2 2 Power supply Specification 2 3 Battery Specification 2 4 Cable Specification 2 5 Communication Specifi...

Page 12: ...ibration IEC 60068 2 6 Frequency Acceleration Amplitude Number of Occurrence 10 f 57 0 075mm 10 times in each direction of X Y Z 57 f 150 9 8 1G Shock Resistance Maximum impact acceleration 147 15G Ap...

Page 13: ...16 6 ETOS 500XP O XL 050F Lithium 3 6V 1 2A 28 x 16 6 2 3 2 Precautions for Use 1 Do not charge disassemble heat put into fire short circuit solder or give a shock to the battery 2 Handling battery i...

Page 14: ...ble to backup up to 2 hours with the internal super cap charged for 3 days or more so be sure to complete the battery replacement within 2 hours The order of the battery exchange and the related photo...

Page 15: ...OS 500XP Battery assembly can be done in reverse order of disassembly Unscrew battery cover to open the mounting cover Remove the mounting cover from the holder Open the battery compartment of the mou...

Page 16: ...and communication speed The following table lists the recommended cable specifications Electrical Feature Appearance Item Unit Single Wire Stranded Wire Conductor No of Core Wire Pair 2 2 Specificati...

Page 17: ...Cable Use Item Name UTP Cable Type Name Enhanced CAT 5 4P Specification 4P Pair X 24AWG Recommended Cable Specification In order to guarantee the Ethernet communication speeds you must use the cables...

Page 18: ...e Cable Maker LG Cable Hewlett Packard H P Structure Fiber Size Core Cladding 62 5 125 Connector Style L C Cable Type Dual Channel Maximum Attenuation 5 dB km Standard Attenuation 4 5 dB km N A Numeri...

Page 19: ...CD 2 5 2 Serial RS 232 RS 422 RS 485 Item Specification Data Bit 7 or 8 Stop Bit 1 or 2 Start Bit 1 Parity Even Odd None Space Mark Synchronization method Asynchronous method Transmission Rate BPS 20...

Page 20: ...GREEN Mode LED Blink during SW Run Remote run STAT YELLOW Status LED ON at the warning state STOP RED Mode LED On at Stop mode 2 6 2 ETOS 150XP 2 6 2 1 ETOS 150XP LED LED Status Name LED Color Operat...

Page 21: ...OW ON at the warning state OFF at normal state STOP RED On at Stop OFF at other states RUN 2 6 4 ETOS 500XP LED SIO 2 6 4 1 SIO RS 232 4Port LED LED Status Description Name Color Operating Status Seri...

Page 22: ...t RX of Serial CH1 TX2 GREEN ON at TX of Serial CH2 RX2 YELLOW ON at RX of Serial CH2 TX3 GREEN ON at TX of Serial CH3 RX3 YELLOW ON at RX of Serial CH3 422 YELLOW ON at RS 422 mode Err RED ON at fram...

Page 23: ...TX2 GREEN ON at TX of Serial CH2 RX2 GREEN ON at RX of Serial CH2 422 YELLOW ON at RS 422 mode Err RED ON at frame error TX3 GREEN ON at TX of Serial CH3 RX3 GREEN ON at RX of Serial CH3 422 YELLOW ON...

Page 24: ...This chapter explains specifications required for installation and wiring of ETOS XP Series Contents 3 1 Power Supply and Connector ETOS 100XP 150XP 3 2 Power Supply and Connector ETOS 500XP 3 3 Ether...

Page 25: ...AC100 240V power input through the power connector in front of the product as shown in the following picture ETOS 100XP ETOS 150XP Input power supply AC 100V 240V Free Voltage 50 60 Hz Power supply mu...

Page 26: ...as follows 1 8 Pin No Name Signal Direction Function Description 1 TD Transmit Ethernet 2 TD Transmit Ethernet 3 RD Receive Ethernet 4 N A 5 N A 6 RD Receive Ethernet 7 N A 8 N A RJ 45 Connector Plug...

Page 27: ...S 232 serial port of the ETOS XP series Serial Port Specification for RS 232 of ETOS XP Series 1 8 Pin No Name Signal Direction Function Description 1 CD DCE notifies DTE of detected carrier 2 RXD Rec...

Page 28: ...RS 232 port of ETOS XP series must be connected as in the following picture 3 TxD 5 SG 2 RxD 3 TxD 5 SG 2 RxD ETOS RJ 45 1 2 3 4 5 6 7 8 9 1 8 Connection Diagram of RS 232 Null Modem When hardware ha...

Page 29: ...D RS 422 Transmit Data 2 TXD RS 422 Transmit Data 3 RXD RS 422 Receive Data 4 RXD RS 422 Receive Data 5 SG1 Signal Ground1 6 TXD RS 422 Transmit Data 7 TXD RS 422 Transmit Data 8 RXD RS 422 Receive Da...

Page 30: ...ion of ETOS XP Series Pin No Name Signal Direction Function Description 1 3 6 8 TRX RS 485 Transmit Receive Data 2 4 7 9 TRX RS 485 Transmit Receive Data The following figure shows the RS 485 connecti...

Page 31: ...31 Appendix Dimension A 1 ETOS 100XP 150XP Unit mm...

Page 32: ...32 A 2 ETOS 500XP Unit mm...

Reviews: