50
5.11
Camera- PTZ
Set the camera audio and P/T/Z environment.
5.11.1. Protocol
Set the protocol to control the P/T/Z controller connected to P/T/Z port on the back panel. P/T/Z controller is also
called receiver or RX if it becomes separated from camera. Default is NONE, which indicates that the P/T/Z
controller protocol is not set. Protocol currently supported is shown below.
1
Ernitec
2400 baud rate
no parity
8bit
1 stop bit
2
Kalatel
9600 baud rate
no parity
8bit
1 stop bit
3
Panasonic
19200 baud rate
no parity
8bit
1 stop bit
4
Pelco D
2400 baud rate
no parity
8bit
1 stop bit
5
Pelco P
4800 baud rate
no parity
8bit
1 stop bit
6
Scc-641
9600 baud rate
no parity
8bit
1 stop bit
7
Sensormatic
2400 baud rate
no parity
8bit
1 stop bit
8
Smart Scan
9600 baud rate
even parity
8bit
1 stop bit
9
VC_C4
9600 baud rate
no parity
8bit
1 stop bit
10
Vicon
4800 baud rate
no parity
8bit
1 stop bit
Set the controller address correctly for each channel after setting the protocol.
5.11.2. Address
Set the P/T/Z driver address of the connected camera.
Check the below items for proper P/T/Z operation.
1.
Check if the protocol of all P/T/Z controllers connected to the system is in accordance.
2.
Check if the communication setting including baud rate of all P/T/Z controllers is in accordance with the assigned
value for that P/T/Z protocol.
3.
Check if the address of all controllers is in accordance with the controller address assigned in the setting
menu for that channel.
4.
Check if the power of the P/T/Z controller is turned on.
5.
Check if wiring to P/T/Z controllers is correct.
Summary of Contents for AV304
Page 1: ......
Page 5: ......
Page 41: ...35 Input a new password After inputting password input the same password again...