User Manual for
Cellswitch 100
Page 16 of 23
STEP 4 – Program the SMS messaged that will be sent when the inputs are
triggered.
DIGITAL INPUT OPTIONS
Input 1 high SMS
1234.F9a”Sensor 1 triggered”
The SMS that will be sent when Input 1 is High (5 to 24 volt).
Input 1 low SMS
1234.F9b”Water level LOW ”
The SMS that will be sent when Input 1 is Low (0 volt or not
connected).
Input 2 high SMS
1234.F9c”Power restored”
The SMS that will be sent when Input 2 is High (5 to 24 volt).
Input 2 low SMS
1234.F9d”Power tripped ”
The SMS that will be sent when Input 2 is Low (0 volt or not
connected).
Input trigger (high) - (Default)
1234.F10a
A SMS will only be sent when an input goes high (5 to 24 volt).
Input trigger (high and low)
1234.F10b
A SMS will be sent when an input goes high or low.
Input trigger (low)
1234.F10c
A SMS will only be sent when an input goes low (0 volt or not
connected).
SMS the reporting numbers (Default)
1234.F11on
The device will SMS the reporting numbers when an input is
triggered.
Do not SMS the reporting numbers
1234.F11off
The device will not SMS the reporting numbers when an input is
triggered.