background image

 

ACCES I/O Products, Inc. 

MADE IN THE USA 

mPCIe-ICM422-4

 

manual revision A1h

 

C

HAPTER 

1:

 

Q

UICK START

 

It is recommended that you install the software package before 
installing the PCI Express Mini Card (mPCIe) in your computer.  You 
can install the software

1

 using either a stand-alone installer 

downloaded from the website or an optional Software Master CD. 

Run the installer you downloaded (or autorun.exe on the Software 
Master CD) and follow the prompts to install the software.   

Please note: during the installation you may be prompted regarding 
the installation of non-WHQL-certified drivers; please carefully 
confirm the digitally signed source of the drivers and accept the 
installation.   

Once the software has been installed, shut down your system and 
carefully install the mPCIe card. 

Re-start your system.  Once the computer finishes booting your 
new serial ports should already be installed and ready for use; you 
can confirm this by launching Device Manager and looking under 

the “Ports” section.  If, for any r

eason, the mPCIe or its ports 

display a warning triangle, right-

click and select “Update Driver”.

 

1

 In Linux or OSX please refer to the instructions in those directories. 

C

HAPTER 

2:

 

I

NTRODUCTION

 

PCI Express Mini Card (mPCIe), a low-profile small-footprint bus 
standard originally intended for adding peripherals to notebook 
computers, has become the de-facto standard for high-
performance, small form-factor devices in many applications. 

 

1-, 2- or 4- port RS422 / 4-wire 485 serial port on mPCIe 

 

Tru-

Iso™ provid

es signal isolation recognized under IPC-

2221B and IEC 60950-1 

o

 

500V port-to-port, 1500V port-to-PC isolation 

o

 

2500 VRMS Max Transient Isolation 

o

 

848 Volt Peak Max Work Isolation 

 

3 Mbps, up to 12M with factory option 

 

RoHS and Industrial temperature standard 

The mPCIe-ICM422 family of cards feature high performance 
16C950-class UARTs. Each port is capable of communication 
speeds up to 921.6kbps and has 128-byte deep transmit and 
receive FIFOs which protect against data loss in multitasking 
operating systems, reduce CPU utilization, and improve data 
throughput. The advanced integrated circuit supports a wide 
variety of custom baud rates, and any rates not otherwise 

achievable can be supported via a factory-installed custom crystal 
oscillator.  

The ports provided by the card are 100% software compatible with 
industry-standard serial COM devices. In addition, they provide 
Tru-

Iso™ port

-to-port and port-to-PC isolation. 

Communication is possible either with custom application 
software, with off-the-shelf applications (such as HyperTerminal), 

or with provided samples and utilities, including WinRISC™ 
(“Windows Really Incredibly Simple Communication”).

 

The serial ports on the device are accessed using a low-profile 
latching 5-pin Hirose connector.  Optional breakout cable kits are 
available, and bring each port connection to a panel-mountable 
DB9-M. 

There are no user-selectable option settings for this device family. 

C

HAPTER 

3:

 

H

ARDWARE

 

These models are full-

length “F1”

 mPCIe devices (30 × 50.95 mm).  

All units are RoHS compliant and support Industrial temperature 
environments (-40°C to 85°C operating, -65°C to 150°C storage.) 

 INCLUDED IN YOUR PACKAGE  

Four-, two-, or one-port mPCIe-ICM422 card 

Available accessories include: 

CAB-mPCIe-1S  One port DB-9 cable accessory kit  
CAB-mPCIe-2S  Two port DB-9 cable accessory kit  
CAB-mPCIe-4S  Four port DB-9 cable accessory kit  

ADAP9  DB-9 Screw Terminal Accessory 

mPCIe-HDW-KIT2  Mounting hardware for 2mm 

mPCIe-HDW-KIT2.5  Mounting hardware for 2.5mm 

Contact the factory for information regarding additional 
accessories, options, and specials that may be available to best fit 
your specific application requirements.  

C

HAPTER 

4:

 

C

ONFIGURATION 

S

ETTINGS

 

This product has no user configurable hardware options. All 
possible configuration settings can be performed through the 
industry standard UART drivers in your operating system. 

 

The RS422 ports are terminated by a 120Ω load in series with a 

0.01µF capacitor across the Rx+/Rx- pair. 

This manual applies to the following models: 

mPCIe-ICM422-4  Four port RS422 Tru-

Iso™ mPCIe device

 

mPCIe-ICM422-2  Two port RS422 Tru-

Iso™ mPCIe device

 

mPCIe-ICM422-1  One port RS422 Tru-

Iso™ mPCIe device

 

Summary of Contents for MPCIE-ICM422-4

Page 1: ...s io 10623 Roselle Street 800 326 1649 http acces io mPCIe ICM422 4 San Diego CA 92121 1506 USA sales accesio com MADE IN THE USA ISOLATED MULTI PORT RS422 PCI EXPRESS MINI CARD HARDWARE MANUAL MODELS MPCIE ICM422 4 MPCIE ICM422 2 MPCIE ICM422 1 ...

Page 2: ...loss in multitasking operating systems reduce CPU utilization and improve data throughput The advanced integrated circuit supports a wide variety of custom baud rates and any rates not otherwise achievable can be supported via a factory installed custom crystal oscillator The ports provided by the card are 100 software compatible with industry standard serial COM devices In addition they provide T...

Page 3: ...he 4 port card violates the component height limit on the back of the card by up to 1 3mm This may result in mechanical incompatibility with some motherboard designs if and only if they place other motherboard components inside the footprint of the full length mPCIe card CHAPTER 6 I O INTERFACE This card provides one 5 pin latching Hirose DF57 connector per serial port The mating connector is the ...

Page 4: ...53 V peak VIORM IEC 60950 1 Reinforced Insulation 848 V peak VIORM IEC 60950 1 Basic Insulation Careful attention has been paid to isolation design including extensive keep out zones and hand routed circuit paths as well as component and material selection CHAPTER 9 CERTIFICATIONS CE FCC These devices are designed to meet all applicable EM interference and emission standards However as they are in...

Page 5: ...TERMS AND CONDITIONS If a unit is suspected of failure contact ACCES Customer Service department Be prepared to give the unit model number serial number and a description of the failure symptom s We may suggest some simple tests to confirm the failure We will assign a Return Material Authorization RMA number which must appear on the outer label of the return package All units components should be ...

Reviews: