Programming 

Relay Time Schedule Programming: 

Relay Time Schedules may be used to control the gate or door 

without the use of an entry code during certain times of the day.  

These schedules can be used to open the gate/door, hold the 

gate/door open for a programmed time or date, and/or release the 

gate/door at a programmed time or date.  The LATCH relay action 

should be used.  To program a Relay Time Schedule: 

1.  Press 

 and hold for 3 seconds until unit beeps. (STATUS) 

2.  Press 

 PAC (PROGRAM) 

3.  Press 

 (RLY OPTS) 

4.  Press 

 (R SCHED)  

5.  Press 

 01-99 Schedule numbers 

6.  Press 

 for new schedule or 

 to edit a schedule 

7.  Press 

 or 

 1-6 for Relay 1 Function, #=Momentary 

8.  Press 

 or 

 1-2 for Relay 1 Event Control, 1 or #=Off 

9.  Press 

 or 

 start date, #=Current date 

10.  Press 

 or 

 end date, #=No end date 

11.  Press 

  or 

for  active  days  of  week.  

#=All days.  (Example: 1=Sunday, 246=MWF) 

12.  Press 

 or 

 for start time.  #=12:00:00 

Time is 12 hour format. 

13.  Press 

 

 for AM/PM setting.  (1=AM, 2=PM) 

14.  Press 

 or 

 for end time.  #=12:00:00 

Time is 12 hour format. 

15.  Press 

 

 for AM/PM setting.  (1=AM, 2=PM) 

16.  Press 

 or 

 1-6 for Relay 2 Function, #=None 

17.  Press 

 or 

 1-2 for Relay 2 Event Control, #=Off 

18.  Press 

 or 

 start date, #=Current date 

20.  Press 

 or 

 end date, #=No end date 

21.  Press 

 or 

 for active days of week.  

#=All days.  (Example: 1=Sunday, 246=MWF) 

 
 
 

Programming 

Relay Time Schedule Programming (Cont): 

21.  Press 

 or 

 for start time.  #=12:00:00 

Time is 12 hour format. 

22.  Press 

 for AM/PM setting.  (1=AM, 2=PM) 

23.  Press 

 or 

 for end time.  #=12:00:00 

Time is 12 hour format. 

24.  Press 

 for AM/PM setting.  (1=AM, 2=PM) 

25.  Press 

 to exit. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Delete Relay Time Schedules: 

To delete a Relay Time Schedule: 

1.  Press 

 and hold for 3 seconds until unit beeps. (STATUS) 

2.  Press 

 PAC (PROGRAM) 

3.  Press 

 (RLY OPTS) 

4.  Press 

 (R SCHED)  

5.  Press 

 01-99 Schedule number 

6.  Press 

 (LOC DEL) 

7.  Press 

 (CONFIRM)  

8.  Press 

 to exit. 

           

7  # 

4  # 

   

#  1 

  # 

  # 

m m  d  d  y  y  # 

m m  d  d  y  y  # 

              # 

h  h  m m  s  s  # 

  # 

h  h  m m  s  s  # 

  # 

  # 

  # 

m m  d  d  y  y  # 

m m  d  d  y  y  # 

              # 

h  h  m m  s  s  # 

  # 

h  h  m m  s  s  # 

  # 

* * 

           

7  # 

4  # 

   

2  # 

* * 

Enter 

Event Control 

Display 

On 

ON 

Off 

OFF 

Default = Off 

OFF 

Enter 

Relay Action 

Display 

None 

NONE 

Momentary 

MOMENT 

Latch 

LATCH 

Latch Timeout 

LTIMEOUT 

Unlatch 

UNLATCH 

Toggle 

TOGGLE 

Toggle Timeout 

TTIMEOUT 

Summary of Contents for DL100

Page 1: ...ccess device Please refer to this manual and qualified personnel for assistance DO NOT install this device unless all entrapment and pinch points are eliminated 1 Revision 2 3 DL1000 Standalone Digita...

Page 2: ...Entry Codes 6 Add Single Customized Codes 7 Delete Single Entry Codes 8 Add Simple Block Entry Codes 8 Add Block Customized Codes 8 Delete Block Entry Codes 9 Auxiliary Input Programming 9 Entry Code...

Page 3: ...feature to prevent unauthorized use 8 Mount all operating devices clearly out of reach of through gates 9 DO NOT install this device unless all potential hazards and pinch points have been eliminated...

Page 4: ...m to a gate operator 1 Connect NO1 to Gate Open Input 2 Connect COM1 to Gate Common 3 Use at least 18AWG or larger wire 4 Important Follow all safety guidelines and precautions when using the system w...

Page 5: ...uxiliary Override inputs To activate Relay 1 1 Connect GND to the open device 2 Connect EXIT 1 to the open device To activate Relay 2 1 Connect GND to the open device 2 Connect EXIT 2 to the open devi...

Page 6: ...s serial number and PAC Serial Number Program Access Code Programming Time Clock Programming The DL1000 has a built in 7 Day Plus time clock for time control of individual codes and relay open schedu...

Page 7: ...date 21 Press or for active days of week All days Example 1 Sunday 246 MWF Programming Add Single Customized Code Cont 21 Press or for start time 12 00 00 Time is 12 hour format 22 Press for AM PM se...

Page 8: ...o customize an entry code settings program each step as needed To program a customized block of codes 1 Press and hold for 3 seconds until unit beeps STATUS 2 Press PAC PROGRAM 3 Press CODE 4 Press ST...

Page 9: ...gramming This programming will set the Relay Functions Event Control and Do Not Disturb DND control of the Auxiliary Inputs All external devices fire boxes key boxes pushbuttons connected to the Auxil...

Page 10: ...USERPREF 4 Press RESET 5 Press to confirm All codes will be cleared 6 Press to exit Turn power off on to reset Programming Strikes Lockout Programming Strikes Lockout helps prevent unauthorized users...

Page 11: ...M 2 PM 14 Press or for end time 12 00 00 Time is 12 hour format 15 Press for AM PM setting 1 AM 2 PM 16 Press or 1 6 for Relay 2 Function None 17 Press or 1 2 for Relay 2 Event Control Off 18 Press or...

Page 12: ...Feature The Do Not Disturb DND mode puts the system into a sleep mode and does not allow entry code or relay activation while DND is On active Entry codes that have been programmed with DND Access ON...

Page 13: ...trikes Lockout feature may be active Wait 3 minutes and retry 2 Make sure the keypad is plugged in correctly Entry Codes will not activate relay 1 Enter the entry code slower A beep should sound and s...

Page 14: ...can cause serious injury or death Read and follow all installation manuals reference manuals and warning label instructions 2 Vehicular gates are for vehicles only Pedestrians must use a separate entr...

Page 15: ...www AccessOneTechnologies com...