background image

FEB100-NT 

Product Manual 

FEB100-NT, Rev A 
 

Page 2 

 

C

ONNECTING

 A

N

 E

LECTRIC

 S

TRIKE

To connect the FEB100-NT to an electric strike: 

1.  Connect two wires from the electric strike to the 

NO and NOC terminals:  

• 

One leg of strike power to NO terminal. 

• 

Same leg of strike power out from NOC 

terminal to the strike. 

• 

Other leg of strike power direct to the 

strike. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C

ONNECTING

 A M

AGNETIC

 L

OCK

To connect the FEB100-NT to an electric strike: 

1.  Connect two wires from the electric strike to the 

NO and NOC terminals:  

• 

One leg of maglock power to NC terminal. 

• 

Same leg of maglock power out from NCC 

terminal to the magnetic lock. 

• 

Other leg of maglock power direct to lock. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

I

NFRARED

 S

ENSOR

 O

VERVIEW

  

 

 

 

 

 

 

 

 

T

IME

 D

ELAY

 A

DJUSTMENT

The time delay can be adjusted from 0.5 to 20 

seconds using the adjustment dial on the left of the 

IR Sensor.  To adjust the time delay: 

1.  Turn the adjustment dial clockwise to increase 

the time delay. 

2.  Turn the adjustment dial counter clockwise to 

decrease the time delay. 

3.  Turning the adjustment dial fully clockwise to 

the end will put the sensor into a toggle mode. 

 

T

OGGLE

 M

ODE

 S

ETTING

The time delay can be turned off and set to a toggle 

mode.  To set the Sensor in toggle mode: 

1.  Turn  the  Time  Delay  Adjustment  dial  clockwise 

to the end. 

 
 

S

ENSOR

 D

ETECTING

 D

ISTANCE

 A

DJUSTMENT

The IR Sensor detecting distance can be adjusted 

from 5cm to 20cm using the adjustment dial on the 

right.  To adjust the detecting distance: 

1.  Turn the adjustment dial clockwise to increase 

the detection distance. 

2.  Turn the adjustment dial counter clockwise to 

decrease the detection distance. 

 
 

M

ANUAL

 O

VERRIDE

The FEB100-NT has a built-in manual override button 

below the IR Sensor to be used if bad weather 

prevents the infrared sensor from working. 

 

NOTE:  The manual override only provides a 

momentary action and does not use the time delay or 

toggle settings of the IR Sensor. 

 

 

 

 

 

 

 

12+  12-  NO  NOC  NC  NCC 

Separate Strike 

Power 

 

 

 

 

 

 

12+  12-  NO  NOC  NC  NCC 

Separate Maglock 

Power 

Wire Terminal 

Time Delay 

Adjustment 

Sensitivity 

Adjustment 

IR Sensor 

Manual 

Override 

Summary of Contents for FEB100-NT

Page 1: ...lling Refer to the manual and qualified personnel for assistance DO NOT install this device unless all entrapment and pinch points are eliminated Revision A FEB100 NT Free Exit Box No Touch Sensor Product Manual Installation Instructions Wiring Instructions ...

Page 2: ...gooseneck post 2 If the mounting holes are not used fill the holes with a plug or sealant to prevent water from entering the box Wall Mounting 1 Mount the system to a wall or flat surface Use appropriate mounting screws or anchors to securely attach the system 2 Never mount the system to a moving gate gate panel or next to a gate that causes vibration to the mounting point Continuous vibration fro...

Page 3: ...justment dial counter clockwise to decrease the time delay 3 Turning the adjustment dial fully clockwise to the end will put the sensor into a toggle mode TOGGLE MODE SETTING The time delay can be turned off and set to a toggle mode To set the Sensor in toggle mode 1 Turn the Time Delay Adjustment dial clockwise to the end SENSOR DETECTING DISTANCE ADJUSTMENT The IR Sensor detecting distance can b...

Page 4: ...can cause serious injury or death Read and follow all installation manuals reference manuals and warning label instructions 2 Vehicular gates are for vehicles only Pedestrians must use a separate entrance Keep all pedestrian traffic away from any vehicular gate No one should cross the path of a moving gate 3 Never allow children to operate or play with gate controls or to play in the area of a gat...

Reviews: