FEB100-NT
Product Manual
FEB100-NT, Rev A
Page 2
C
ONNECTING
A
N
E
LECTRIC
S
TRIKE
:
To connect the FEB100-NT to an electric strike:
1. Connect two wires from the electric strike to the
NO and NOC terminals:
•
One leg of strike power to NO terminal.
•
Same leg of strike power out from NOC
terminal to the strike.
•
Other leg of strike power direct to the
strike.
C
ONNECTING
A M
AGNETIC
L
OCK
:
To connect the FEB100-NT to an electric strike:
1. Connect two wires from the electric strike to the
NO and NOC terminals:
•
One leg of maglock power to NC terminal.
•
Same leg of maglock power out from NCC
terminal to the magnetic lock.
•
Other leg of maglock power direct to lock.
I
NFRARED
S
ENSOR
O
VERVIEW
:
T
IME
D
ELAY
A
DJUSTMENT
:
The time delay can be adjusted from 0.5 to 20
seconds using the adjustment dial on the left of the
IR Sensor. To adjust the time delay:
1. Turn the adjustment dial clockwise to increase
the time delay.
2. Turn the adjustment dial counter clockwise to
decrease the time delay.
3. Turning the adjustment dial fully clockwise to
the end will put the sensor into a toggle mode.
T
OGGLE
M
ODE
S
ETTING
:
The time delay can be turned off and set to a toggle
mode. To set the Sensor in toggle mode:
1. Turn the Time Delay Adjustment dial clockwise
to the end.
S
ENSOR
D
ETECTING
D
ISTANCE
A
DJUSTMENT
:
The IR Sensor detecting distance can be adjusted
from 5cm to 20cm using the adjustment dial on the
right. To adjust the detecting distance:
1. Turn the adjustment dial clockwise to increase
the detection distance.
2. Turn the adjustment dial counter clockwise to
decrease the detection distance.
M
ANUAL
O
VERRIDE
:
The FEB100-NT has a built-in manual override button
below the IR Sensor to be used if bad weather
prevents the infrared sensor from working.
NOTE: The manual override only provides a
momentary action and does not use the time delay or
toggle settings of the IR Sensor.
12+ 12- NO NOC NC NCC
Separate Strike
Power
12+ 12- NO NOC NC NCC
Separate Maglock
Power
Wire Terminal
Time Delay
Adjustment
Sensitivity
Adjustment
IR Sensor
Manual
Override