ELECTRICAL PREP
ARA
TION
ELECTRICAL PREPARATION
All electrical wiring must be installed in accordance with the National Electrical Code and with all local codes. All wiring shall be done
by a qualified electrician. Run one, two or three branch circuits (as required) from the main electrical service panel to the pump area
of the framing structure to provide power to the unit.
Electrical components have specific wiring requirements. Refer to the matrix below for the electrical supply requirements for the air
massage bathtub and factory installed components.
Branch circuits must be rated for 110 – 120 volts. Use 12 Gauge, 3 conductor cable for the circuits. If the length run exceeds 100
feet check with local codes for requirements. Install moisture proof junction box(s) 6” above the floor at the pump end of the framing
for each circuit.
NOTE: DO NOT INSTALL THE JUNCTION BOX(S) WHERE IT CAN BE REACHED WHILE SITTING OR STANDING IN THE TUB OR
TOUCHING THE FAUCETS.
AUTO DRAIN™, AROMATHERAPY, AIR REQUIREMENTS
This section lists the factory installed components of the Air Massage Systems.
Systems
Electrical Ra
ti
ng
Circuit 1
Dedicated
Circuit
Air Massage w/ Auto Drain™ & Aromatherapy
20 Amp GFCI
All electrical connections must be carried out b y a certified electrician in accordance with local electrical requirements and codes.
ELECTRICAL PREPARATION