background image

Access Tubs

 

5701 NW 35 Avenue Miami, FL 33142 PHONE: 877-249-2388 FAX: 866-560-1060 www.accesstub.com

Page 6

Access Tubs

SAFETY

SAFETY

PRE-INSTALLATION*

* All Walk-In Bath Tubs are 100% water tested at the factory certified to be free of leaks. Transportation and mishandling may cause leaks. It is necessary to test the bathtub while there is access to 
all sides of the bathtub.

READ AND FOLLOW ALL INSTRUCTIONS

•   Place the tub on a completely flat surface in an area where it may be drained after testing.

•  Close the drain and fill the tub until it is above the highest jet. If it’s a soaker fill up to normal water height level.

•  Allow the water to stand in tub for 30 minutes and then inspect all plumbing and seals for leaks. 

•  If tub is jetted, supply electric to unit and run for 10 minutes and inspect for leaks. Inspect the unions around the pump; if leaks 

persist from the unions after tightening; loosen the unions and insure the O-ring is seated properly. 

NOTE: IF THE PUMPS DO NOT OPERATE, CHECK THE BREAKER TO ENSURE POWER IS ON AND THE CABLE CONNECTING THE 

CONTROLS TO THE PUMP IS ATTACHED.

WARNING!

 DO NOT RUN ANY PUMPS UNLESS THE TUB IS FILLED WITH WATER TO PROPER 

LEVEL. DAMAGE DUE TO DRY RUNNING PUMPS IS NOT COVERED UNDER WARRANTY. FAILURE TO 

PERFORM THESE TESTS BEFORE INSTALLATION WILL MAKE THE INSTALLER LIABLE FOR FUTURE 

REPAIR COSTS.

Summary of Contents for 3060WCA AIR

Page 1: ...com Page 25 AccessTubs INSTALLATION OPERATING INSTRUCTIONS INSTALLATION OPERATING INSTRUCTIONS 3060WCAAIR ACCESS TUBS 5701 NW 35 Avenue Miami FL 33142 Phone 877 249 2388 Fax 866 560 1060 info accesstub com http www accesstub com MODEL Costco Item 558600 580183 Right Costco Item 558596 580185 Left ...

Page 2: ...riatinginthecomfortofyourownhome FEATURES Availablein whiteonly 16massaging airjets Aromatherapyfragrancereleasesystemincluded 1 HP electricair pumpmotor Faucet included w handshower Doublelatch doorsystem bottomlatch sidelatch Tubleveling systemconsistingofsix 6 adjustablelevelingfeet Built in safetygrabbar Slip resistant floorandslipresistantseat Triplegelcoat strengthenedwithafiberglassbacking ...

Page 3: ...ISMANUAL 4 UNPACKINGTHEUNIT 5 PRE INSTALLATION 6 INSTALLATIONPREPARATION 7 ELECTRICALPREPARATION 8 INSTALLATIONPROCEDURES 9 DRAINCONNECTION 10 CONNECTINGTHE AUTODRAINTM 11 INSTALLATIONAND EXTENSIONPANELS 12 FAUCETINSTALLATION 13 OPERATINGSAFETY INSTRUCTIONS 14 OPERATINGINSTRUCTIONS 16 TUBCONTROLS 18 CLEANINGANDMAINTENANCE 19 WARRANTY 20 RETURNPOLICY 22 PRODUCTREGISTRATIONCARD 23 TABLE OF CONTENTS ...

Page 4: ...b on the market today Until recently if you have difficulty getting in and out of a bathtub it was almost impossible for you to take a bath Access Tubs specializes in accessibility and security Safe transfers in and out of the bathtub are the most critical part of bathing safely Access Tubs is committed to providing a complete bathing experiencefortheelderlyandmobility impaired THANKYOUFOR YOUR PU...

Page 5: ...nsure that your warranty is registered and confirmed with the manufacturer please take a few moments to complete sign and returntheProduct RegistrationCard below within30days WARRANTYCONFIRMATION By returning this Product Registration Card we confirm the date of purchase for your new product This confirmation will allow AccessTubs to processanywarrantyclaims PURCHASEREGISTRATION The information pr...

Page 6: ...FECTORDAMAGE INTHEEVENTOFAPROBLEM THEUNITMUSTNOTBEINSTALLED IFTHECRATEORTHEPRODUCT HAS BEEN DAMAGEDDURINGSHIPPING PLEASECALLUSIMMEDIATELY THISPRODUCTMUSTBEINSTALLED BY A LICENSED CERTIFIED CONTRACTOR LICENSED PLUMBERS AND ELECTRICIANS SHOULD BE EMPLOYED TO INSURE PROPER INSTALLATION INSTALLERS ASSUME ALL LIABILITY FOR THE CORRECT INSTALLATION PROCEDURES ONLY ACCESSORIES AUTHORIZED BY THE MANUFACTU...

Page 7: ...plumbingandcausingaleak INSPECTINGTHEUNIT Immediately inspect the unit for damage even if there is no carton damage Once the unit is installed surface damages will be assumed to beinstallationrelatedifnotreportedatthispoint PLACINGTHEUNIT Pleasenotethataninstaller s assumesfullliabilityfordamagestothewalk inbathtubaftertheunitisinstalledinthe cradle niche WHATSINSIDETHEPACKING Inside thepackageyou...

Page 8: ...lthetubuntilitisabovethehighestjet Ifit sasoakerfilluptonormalwaterheightlevel Allowthewater tostandintubfor30minutesandtheninspectallplumbingandsealsforleaks Iftubisjetted supplyelectrictounitandrunfor10minutesandinspectforleaks Inspecttheunionsaroundthepump ifleaks persist from theunionsaftertightening loosentheunionsandinsuretheO ringisseatedproperly NOTE IFTHEPUMPSDONOTOPERATE CHECKTHEBREAKERT...

Page 9: ...evel Ifthefloorisnotlevel adjustall6levelingfeettoperfectlylevelthetub NOTE IT IS IMPORTANT THAT ALL LEVELING FEET ARE COMPLETELY TOUCHING THE FLOOR ANDLEVELFORTHEDOORSYSTEMTOWORKPROPERLY 2 Checkto ensurethatthedrainpipinghasbeen roughed in attheproperlocation 3 Ensure that the proper electrical service has been installed at the pump location See electrical requirements in the manual on following ...

Page 10: ...massagebathtub andfactoryinstalledcomponents Branch circuits must be rated for 110 120 volts Use 12 Gauge 3 conductor cable for the circuits If the length run exceeds 100 feetcheckwithlocalcodesforrequirements Installmoistureproofjunctionbox s 6 abovetheflooratthepumpendoftheframing foreach circuit NOTE DONOTINSTALLTHEJUNCTIONBOX S WHEREITCANBEREACHEDWHILESITTINGORSTANDINGINTHETUBOR TOUCHING THE F...

Page 11: ...ACCESSPANEL FORTHE PUMP MOTOR GENERALGUIDE THROUGH Installtub waste overflowaccordingtoinstructions seepage10 Standardinstallation Afterframingisacomplete seeattacheddiagrams setproductinplacetomakecertainthatthetubcan be properly leveled Caution If a walk in bathtub is not resting on all leveling feet water will not drain properly and may cause the door to leak seepage7 Verifytheproduct slevelbyc...

Page 12: ...rain whichallowsthedraintobeopenedorclosed Oncethecomponentsoftheoverflowaresecuredintoplace turntheoverflowknobtothe openandclosedpositiontoensureproperfunction Thecapandstemwillmoveupanddown openingandclosingthedrain Figure1 Your walk in tub also has a door drain to remove excess water from the door after eachuse Fromtheundersideoftheunit ahoseisconnectedtothedoordrainwith acheckvalve Thishosean...

Page 13: ...nection to a minimum 1 sanitary drain line Use UPC Approved PVC Glue primer and Schedule 40 1 pipe Do not change or modify the location and or piping of the Back Flow Preventer The sanitary tee is installed directly above the drain tee with clearance not greater than 1 Dry fit the drain overflow assembly to the sanitary drainage pipe and check for proper fit Glue the Auto Drain pipe and drain over...

Page 14: ...nue Miami FL 33142 PHONE 877 249 2388 FAX 866 560 1060 www accesstub com Page 12 AccessTubs SIDE ACCESS PANELS FOR 3 SIDE ENCLOSURE ASSEMBLY PLACEMENT Verify accessto unit ssystemfromoneofthesideenclosures OPERATING INSTRUCTIONS ...

Page 15: ...Page 13 AccessTubs FAUCET INSTALLATION fixing nut fixing nut fixing nut hot control handle cold control handle spout shower head diverter rubber washer fiber washer valve body gasket steel braded 19 hose steel braded 19 hose 72 shower hose local water line hot water cold water OPERATING INSTRUCTIONS ...

Page 16: ...ase in body temperature This can be a serious medical condition and all bath users are cautioned against lengthy immersion at high water temperatures Should you become light headed dizzy or nauseous immediatelygetoutofthebathandcooloff Risk of electric shock do not permit electric appliances such as a hair dryer lamp telephone radio or television within four feet of thisbathtub Never drop or inser...

Page 17: ... the GFCI fails to operate in this manner there may be a ground current flowing indicating the possibility of an electric shock Do not use this massage bathtub Disconnect the jet massage bathtub and havetheproblem correctedbyaqualifiedservicerepresentativebeforeusing Toreducetheriskofelectricalshock thededicatedelectricalsupplycircuit s mustbegrounded Todothis connectthethirdlegof the 3 conductor ...

Page 18: ...ntering and exiting the tub It is recommended to leave the door in the open position when the tub is not inuse The blower is operated by the air control button which starts the air flow see page18 PURGECYCLE All air blowers are equipped with a purge cycle to remove residual water from the lines The cycle will begin approximately 30 minutesafter theunit isturnedoffandwillcontinuefor1 2minutes WARNI...

Page 19: ... PHONE 877 249 2388 FAX 866 560 1060 www accesstub com Page 17 AccessTubs NOTE THE AIR HEATER IS DESIGNED TO HEAT THE JETTED AIR AND BUBBLES BUT IS NOT DESIGNED TO INCREASE THE WATER TEMPERATURE HEATSETTINGSARENOTADJUSTABLE OPERATING INSTRUCTIONS ...

Page 20: ...S TUBCONTROLS 1 2 AIRCONTROL BLOWER UsedtoturntheairjetsON orOFF AUTODRAINTM Efficientlydrainsthewaterinunder60seconds AROMATHERAPY Twist off the cap and insert your choice of Aromatherapy beads When the air blower is actived the circulating air will releasethefragrancethroughthebubbles 1 2 3 OPERATING INSTRUCTIONS AROMATHERAPY 3 ...

Page 21: ... asdishwashingmachinedetergent Turn on whirlpoolsystemandrunfor10minutes Drain tub completely Filltub with coldwaterabovejets Turn on whirlpoolsystemandrunfor15minutes Drain tub completely Cleaningthesuctioncover Cleanandremoveanyhairorlintfromthesuctioncover seeimagebelow Onamonthlybasis unscrewthesuctioncoverandcleanawayanyhair lintordebrisfromthecoverandhousing thenremountthecoverinplace Some s...

Page 22: ...r any property for any reason including but not limited to manufacturer defects or improper installation Manufacturer will assume no responsibility for the loss of the system inconvenience due to loss damage to real or personal property or any other consequential damage Manufacturer will not be liable for any incidental expenses or material charges in connection with removal or replacement of the ...

Page 23: ...proper maintenance The replacement door seal will be issued to the end user and it will be the responsibility of the end user to determine the means of installation Manufacturer will not be liable for any incidental expenses or material charges in connection with removal or replacement of the door seal NOTE TO THE EXTEND PERMITTED BY LAW ALL IMPLIED WARRANTIES INCLUDING THOSE OF MERCHANT ABILITY A...

Page 24: ...tionedinthewarranty thefollowingproceduresapply Requestsfor returnsand orexchangesmustbemadewithin30daysofreceiptofproduct Theproductmustbeinitsoriginal packaging and receivedatAccessTubs insaleablecondition Allreturnswillreceivea20 restockingfeeplusall freight costs oftheoriginalshipmentandreturnshipmenttoAccessTubs Allrequestsfor returnmustfirstbeapprovedbyAccessTubs andhaveanassignedReturnedMer...

Page 25: ...on Card Name Address City State Zip Phone Date of Purchase Dealer Address Installed by Address State Phone State Zip I have read the Access Tubs Owner s Manual carefully and understand and agree that any installation operation or maintenance of the walk in bath tub must be done strictly in accordance with instructions and guidelines contained in the Access Tubs owner s manual and installation guid...

Page 26: ...Access Tubs 5701 NW 35 Avenue Miami FL 33142 PHONE 877 249 2388 FAX 866 560 1060 www accesstub com AccessTubs INSTALLATION OPERATING INSTRUCTIONS INSTALLATION OPERATING INSTRUCTIONS America sWalk InTub ...

Reviews: