DKY
(RF-LEARN)
(Figure 4)
10 sec
DAL
(RF-LEARN)
Step 2: System Learning
Step1:
Press and Hold the Press SET button for 3s, When LED shows “LEA” then release SET, then the motor runs the
system learning procedure automatically, once learning completed shows “D-G” or “S-G”
(No remote required)
Note: Please check the parameter setting of “FI”(Dual/Single) before going into system learning.
Restore system default setting
Press and Hold the UP + SET + DOWN button for 5s and panel restores back to default setting
Note:
1) LED Shows “D-G” tells the system learning has be completed for Dual Gate installation
2) LED Shows “S-G” tells the system learning has be completed for Single Gate installation
A) Dual Gate:
(1) Slave Gate Close
→
(2) Master Gate Close
→
(3) Master Gate Open
→
(4) Slave Gate Open
→
(5) Slave Gate Close
→
(6) Master Gate Close
Press
3 Sec
1
2
3
10
11
12
13
14
LED1
LED2
LED3
ON
OFF
UP
SET
D-G/S-G
LEA
1
15
Opening your life
AC24NE