LED Display
Definition
Parameter
Table
Description
Auto-closing
Reverse mode in
opening
Reverse point on
opening
Modo de reversa en
cierre
Punto de reversa en
cierre
Velocidad de marcha
Tiempo de ignorar los
valores de sensibilidad
durante la marcha
F9
F10
F11
F12
F13
F14
F15
F9-0
F9-1
F9-2
F9-3
F9-4
F9-5
F9-6
F9-7
F9-8
F10-0
F10-1
F10-2
F11-1
F11-2
F11-3
F11-4
F11-5
F12-0
F12-1
F12-2
F13-1
F13-2
F13-3
F13-4
F13-5
F14-1
F14-2
F14-3
F15-0
F15-1
F15-2
F15-3
F15-4
Function OFF
3 sec
10 sec
20 sec
40 sec
60 sec
120 sec
180 sec
300 sec
disabled
2 seconds
Total reverse
It falls back within 95% of
route; stops within 5%.
It falls back within 90% of
route; stops within 10%.
It falls back within 85% of
route; stops within 15%.
It falls back within 80% of
route; stops within 20%.
It falls back within 75% of
route; stops within 25%.
Disabled
2 seconds
Total reverse
It falls back within 95% of
route; stops within 5%.
It falls back within 90% of
route; stops within 10%.
It falls back within 85% of
route; stops within 15%.
It falls back within 80% of
route; stops within 20%.
It falls back within 75% of
route; stops within 25%.
Full speed
Average speed
Slow speed
After starting the engine 0 seconds
After starting the engine 0.5 seconds
After starting the engine 1.0 seconds
After starting the engine 1.5 seconds
After starting the engine 2.0 seconds
1. Auto-close mode activates when the
gates move to the end position or
stopped manually. If the transmitter,
push button, or the key selector is
activated before the auto-close
counting, the gate will close
immediately.
2. The factory setting is "F9-0".
1. The original parameter is "10-0".
1. The original parameter is "11-3".
2. Reverse logic refers to parameter
10
3. Reverse speed refers to parameter
6.
1. The original parameter is "12-2".
1. The original parameter is "13-3".
2. Reverse logic refers to parameter
10
3. Reverse speed refers to parameter
6.
1. The original parameter is "14-1".
1. The original parameter is "15-4".