LED Display
Definition
Parameter
Table
Description
F16
Sensibilidad
F16-0
F16-1
F16-2
Obstacle detection considered as
overcurrent immediately.
Obstacle detection considered as
overcurrent after 0.1 seconds.
Obstacle detection considered
as overcurrent after 0.2
seconds.
1. The original parameter is "16-0"
Photocell Function Mode
Pedestrian Mode
Flashing Light
Photocell Activation
Photocell 2 Activation
Alarm Buzzer
Electric Latch Mode
LED Direction
Dual / Single Gate
F16-3
F16-4
F16-5
FA-1
FA-2
FA-3
FA-4
FB-0
FB-1
FC-0
FC-1
FD-0
FD-1
FE-0
FE-1
FF-0
FF-1
FG-0
FG-1
FH-0
FH-1
FI-1
FI-2
Obstacle detection considered
as overcurrent after 0.3
seconds
Obstacle detection considered
as overcurrent after 0.4
seconds
Obstacle detection considered
as overcurrent after 0.5
seconds
Mode 1
Mode 2
Mode 3
Mode 4
Function OFF
Function ON
Function OFF
Function ON
Function OFF
Function ON
Function OFF
Function ON
Function OFF
Function ON
Standard Gate Opening
Release Gate Tension before
Opening (Gate Reversing for 0.25s)
For articulated arm
For swing gate
Single Gate
Dual Gate
FA
FB
FC
FD
FE
FF
FG
FH
FI
1. Please see 7.3 photocell adjustment
for photocell logic
2. The factory setting is "FA-1"
1. El parámetro original es "FB-1".
1. When function FC-1, the light will
flash for 3 seconds
before the gate operates. If set OFF,
the flash light will
operate with motor at the same time.
2. The factory setting is "FC-0".
1. The factory setting is "FD-0".
1. The factory setting is "FE-0".
1. The factory setting is "FF-0".
1. If the function is FG-1, the motor will
be reversed for
0.25 sec. to release the tension.
2.The factory setting is "FG-1".
1. The factory setting is "FH-1".
1. The factory setting is "FI-2".
1
21
Opening your life
AC24NE