SWITCH SETTINGS

CONFIGURATION

LINK OUT/TERMINATE

Determines whether the DMX/RDM Thru port is open or internally terminated. 

 

If several RDS 6 units are connected in series, this switch must 
be set in the 

Link Out/

 position on all units 

except

 the final 

one in the chain. 

 

If a single RDS 6 is used or the unit is the final one in a 
chain, this switch must be set in the 

Terminate

 position. 

This ensures that the DMX line (into the unit) is correctly 
terminated. 

DMX/RDM

Determines whether RDM functionality is enabled (ie, that bi-directional communication 
back from the devices is permitted). Some devices that do not correctly implement the full 
DMX512A timing standard can exhibit flickering when RDM is enabled.   

 

Set in the 

DMX

 position if bi-directional RDM services are not 

required and some devices are being affected. 

 

Set in the 

RDM

 position to allow full bi-directional operation 

to take place.  

Summary of Contents for RDS 6

Page 1: ...User guide RDS 6...

Page 2: ......

Page 3: ...ODUCTION 2 Welcome 2 Safety maintenance and cleaning 2 INSTALLATION 3 Mounting 3 Power 3 Fuse replacement 3 Data connections 4 Indicators 4 CONFIGURATION 5 Switch settings 5 FURTHER INFORMATION 6 Spec...

Page 4: ...ted controlling device SAFETY Ensure that the power input is supplied from a correctly fused earthed and environmentally protected location MAINTENANCE CAUTION Always isolate mains power before starti...

Page 5: ...th The power requirements are as follows Voltage 100 277VAC 50 60Hz autosensing Power 14 4W The power cord color designations are as shown here Note Apply power to the unit only once all connections h...

Page 6: ...rts of each connector are suitable for cable cores in the range 24 to 14 AWG 0 2 to 2 08mm2 INDICATORS POWER The red indicator illuminates when mains power is applied to the unit SIGNAL The green indi...

Page 7: ...in this switch must be set in the Terminate position This ensures that the DMX line into the unit is correctly terminated DMX RDM Determines whether RDM functionality is enabled ie that bi directional...

Page 8: ...onnector types 3 way 3 5mm pitch suitable for 24 to 14 AWG 0 2 to 2 08mm2 wire connections Power Consumption 14 4W 0 12A at 120VAC Fuse 5 x 20mm glass 1A quick acting F1L250V Finish Black IP Rating IP...

Page 9: ...7 www acclaimlighting com DIMENSIONS Weight 1 25 lbs 570g...

Page 10: ...rd party items not manufactures by Acclaim lighting During the period specified above Acclaim Lighting will replace defective parts at its expense and will absorb all expenses for warranty service and...

Page 11: ......

Page 12: ...www acclaimlighting com...

Reviews: