background image

 

 

Quick Reference Guide

 

 

 

 

Page 4 of 12 

 

Revised: October 21, 2004 @ 9:55 AM 

 How to SAVE USER SETUPS

.

 

This procedure allows you to SAVE USER SETUP menu settings under one of four USER memory locations. 

1. Press 

the 

green 

C L I P   P L A Y

 button (this is necessary only if the lamp below the button is not already illuminated). 

2.  Press the appropriate CHANNEL button that has an analog STATUS OVERLAY video monitor display. 

3. Press 

the   button.  Press the 

 button again to select FULL SCREEN menu display. 

4. Press 

the   button a few times to exit from any SUBMENU that may be active.  To verify you’re in the HOME 

MENU position; you will see a list of SUBMENUS with a title: “ABEKAS 6000 HOME MENU” on the menu display. 

5.  From the HOME MENU, select the SYSTEM SETUP submenu using the rotary knob on the Abekas 6000 control 

panel; press the 

T A K E

 button to enter the submenu. 

6.  From the SYSTEM SETUP submenu, use the rotary knob to select the USER SETUP SAVE/RECALL submenu; 

then press the 

T A K E

 button. 

7.  From the USER SETUP SAVE/RECALL submenu, select SETTINGS and then press the 

T A K E

 button. 

8.  Using the rotary knob, select the user memory (1-4) under which user you wish to SAVE the menu settings; and 

then press the 

T A K E

 button. 

9.  Using the rotary knob, select SAVE SETTINGS; and then press the 

T A K E

 button. 

10.  A confirm prompt will appear in the control panel, asking if you wish to SAVE SETTINGS under the USER memory 

you have chosen.  If you wish to continue, press the 

E N T E R

 button. 

11.  If desired, repeat these steps to SAVE SETTINGS under other user memory locations. 

12. Press the   button three times to return to the HOME MENU. 

 How to RECALL USER SETUPS

.

 

This procedure allows you to RECALL USER SETUP menu settings from one of four USER memory locations. 

1. Press 

the 

green 

C L I P   P L A Y

 button (this is necessary only if the lamp below the button is not already illuminated). 

2.  Press the appropriate CHANNEL button that has an analog STATUS OVERLAY video monitor display. 

3. Press 

the   button.  Press the 

 button again to select FULL SCREEN menu display. 

4. Press 

the   button a few times to exit from any SUBMENU that may be active.  To verify you’re in the HOME 

MENU position; you will see a list of SUBMENUS with a title: “ABEKAS 6000 HOME MENU” on the menu display. 

5.  From the HOME MENU, select the SYSTEM SETUP submenu using the rotary knob on the Abekas 6000 control 

panel; press the 

T A K E

 button to enter the submenu. 

6.  From the SYSTEM SETUP submenu, use the rotary knob to select the USER SETUP SAVE/RECALL submenu; 

then press the 

T A K E

 button. 

7.  From the USER SETUP SAVE/RECALL submenu, select SETTINGS and then press the 

T A K E

 button. 

Continued on next page… 

Summary of Contents for Abekas MultiFlex 6000

Page 1: ...is you may power ON either of the two redundant power supplies first in a given chassis All power supplies are located in the front of the chassis near the bottom the power switch is located on the fa...

Page 2: ...the button is not already illuminated 2 To ACQUIRE a given video channel be sure the lamp below the channel button that you wish to ACQUIRE is NOT illuminated If the lamp is RED you must first RELEASE...

Page 3: ...NU position you will see a list of SUBMENUS with a title ABEKAS 6000 HOME MENU on the menu display 5 From the HOME MENU select the SYSTEM SETUP submenu using the rotary knob on the Abekas 6000 control...

Page 4: ...rotary knob select SAVE SETTINGS and then press the T A K E button 10 A confirm prompt will appear in the control panel asking if you wish to SAVE SETTINGS under the USER memory you have chosen If yo...

Page 5: ...n you wish to RECORD on for example press the C h A button The lamp below the CHANNEL button should be illuminated GREEN if not follow the procedure To ACQUIRE a Video Channel starting on page 2 above...

Page 6: ...video channel Alternative Method 1 Press the green C L I P P L A Y button this is necessary only if the lamp below the button is not already illuminated 2 Press the specific CHANNEL button C h A C h B...

Page 7: ...e eight video channel buttons C h A C h B C h C etc and verify the clip ID s are not cued or to be really sure just load clip ID 0 BLACK into each of the video channels before performing DELETE see Ho...

Page 8: ...initiated within a single Abekas 6000 chassis the process will be performed rather quickly since the CLIP ID is only being change to a new CLIP ID MOVE The clip s video audio and key material is not p...

Page 9: ...utton 5 Using the numeric keypad type the clip ID that you wish to COPY this clip TO 6 Press the button 7 Press the E N T E R button to start the clip COPY operation COPYING a RANGE of Clips 1 Press t...

Page 10: ...the CLIP ID s will CUE on the video CHANNEL 6 Press to toggle between the BROWSE display categories CLIP LENGTH COMPRESSION etc 7 Press the green C L I P P L A Y button to EXIT the BROWSE function Loc...

Page 11: ...F Y buttons to execute the TRIM A confirm prompt will appear in the LCD display before the clip is finally TRIMMED 7 Press the E N T E R button to execute the TRIM How to TITLE Clips You may TITLE cli...

Page 12: ...of 100 play speed For example for one quarter play speed type 25 4 Press the button 5 To return PLAYING a CLIP at 100 NORMAL play speed press the button How to LOOP Clips This will allow you to LOOP s...