Hardware and physical integration guideline PCR Sensor A111
Page 18 of 32
© 2022 by Acconeer
– All rights reserved
2022-03-08
Figure 17. Impact of the radome-to-sensor distance on the radiation pattern (H-plane). Amplitude is stated in one
direction (Tx or Rx side). For Radar Loop Gain (RLG) the values will be doubled.
It is not recommended to place the cover directly on the sensor. Figure 18
shows the radiation pattern
on the H-plane when the cover (ABS plastic sheet) is located on top of the sensor. In comparison with
Free Space, there is around 3 dB loss on both max. power and total radiated power for this case.
Figure 18. Radiation pattern on H-plane, cover placed directly on the sensor vs Free Space. Amplitude is stated in one
direction (Tx or Rx side). For Radar Loop Gain (RLG) the values will be doubled.