background image

TOUCH SCREEN PAPERLESS RECORDER

 

            

www.accsyselectronics.com

 

 

Page 4  

 

Power  
 

        Requirements: 100 to 240 VAC, 50/60Hz. 20 VA max. Optional 24 VDC  
 

Power Fail Protection

  

Programmed parameters stored in non-volatile memory. Clock battery backed. Clock battery to be replaced 
once in 5Years, one 3V Lithium cell easily replaceable. 
Transmitter Power supply Output: Optional isolated 24Vdc@120mA output 

 

Input / Output 

        Relay Output : 2 relay outputs, (normally open, Close & pole contacts) rated at 30 VDC @ 0.5A or 
230Vac @ 5Amp Max.Additional relay outputs (optional) : 12 Relay card; separate DIN rail 
Mounting Card interfaced with RS-232 or RS-485 interface with this unit 
 

 Memory specification  
 

     Internal memory: 20,000 Reading per channel. 
 
     The data logger consists of internal memory storage capacity of above specified range provides a wide 
range of application in data storage for all channels individually 

 
Optional Higher Capacity Memory 

     Internal memory: 2 

– 4 GB for Higher Data Storage

 
Recording data on storage media 
 

Using the Setup menu, the user can log the data in internal memory. If this memory is full the logged data can be 
transferred to external storage media connected on USB Port. 
 

Record rate            8 channel           16 channel 

   1 Sec                      9 Hrs                 4.5 Hrs 
   10 Sec                    90Hrs                45 Hrs 
   1 min                      540 Hrs             270 Hrs 
   10 min                    5400 Hrs           2700 Hrs 

The above table shows the number of maximum readings can be stored internal memory by changing record time After 
the above prescribed time the data must be transferred to USB storage media so as internal memory get free to store 
the new readings . 

 

Display 

       Type: Color Active Matrix TFT Liquid Crystal Display 
       Size: 8 inch diagonal, Resolution:

 

640 (W) x 480 (H) pixels 

       Interface: Resistive analog touch screen control 
       Display Modes: Graphic trending (horizontal), Bar Graphs( Vertical ) 
       Digital Readout (Single or multi-channel), Alarms and event log settable. 
       Historical trends: In PC Software. 
       Display Windows: Time/Date, Graphics (bars, large digital, graph) Disk 
       Status, System Status, Menu Button Bar, Alarms/ events

 

 

 
 
 
 
 
 
 
 
 
 

Summary of Contents for ARC2020

Page 1: ...nics com Page 1 USER MANUAL MULTI COLOR TOUCH SCREEN PAPERLESS RECORDER MODEL ARC2020 ACCSYS ELECTRONICS 140 6B GOLDEN INDUSTRIAL ESTATE JAWAHARLAL NEHRU ROAD GERUGAMBAKKAM CHENNAI 600122 Tel 044 6050...

Page 2: ...ng INSTALLATION Installation Location Install the control panel in a location that meets the following criteria 1 Little or no mechanical vibration 2 No corrosive gases 3 Minimal temperature fluctuati...

Page 3: ...o 50 ohm Open and short circuit detection Type Range C Accuracy C 100 ohm Pt 385 200 to 400 C 0 2 C Recording Recording Rates User programmable from 1 sample per second to 1 sample every 10 hours Data...

Page 4: ...her Capacity Memory Internal memory 2 4 GB for Higher Data Storage Recording data on storage media Using the Setup menu the user can log the data in internal memory If this memory is full the logged d...

Page 5: ...11 Compliant Software Web server Based Software Safety and Environmental Operating Range 0 C to 60 C 10 to 90 RH non condensing Dimension Bezel dimension 195 H x 300 W x 5mm above panel Unit dimension...

Page 6: ...TOUCH SCREEN PAPERLESS RECORDER www accsyselectronics com Page 6...

Page 7: ...nics com Page 7 OPERATING PARAMETER SETTING Switch ON the device the following display will show the channel readings It will take a few seconds CONFIGURATION SETTING Click CONFIG in the display Enter...

Page 8: ...DER www accsyselectronics com Page 8 After entering the password the setting screen will be displayed as shown below TIME DATE SETTINGS In Setting SET Real Time Clock Set the real time date details Cl...

Page 9: ...w accsyselectronics com Page 9 LOG TIME SETTINGS In Setting SET Log Time Set the Log Time Of The Logger Click Ok to save the settings PASSWORD SETTINGS In Setting Click SET Password this feature is us...

Page 10: ...rm range from the specified values Low 999 High 9999 RANGE Set the range with respect to the Sensor type specification REF PAGE NO 3 OFFSET Set the offset range from 999 to 999 Default set 0 DECIMAL S...

Page 11: ...front panel of the Logger In Setting Click COPY Memory this feature is used to copy the Logger memory in to the Pen Drive If USB 2 0 drive is not inserted in the drive an error screen PEN DRIVE PROBL...

Page 12: ...an Ink jet printer through the PRINTER PORT provided in the back panel of Logger In Setting Click PRINT Memory the entire memory will be printed GRAPH After completing all the Settings Click HOME ico...

Page 13: ...ERMINAL DETAILS ID NUMBER In Setting ID NUMBER SETTING for Multi Logger Software DATA LOGGING OFF Logging Off The Data Logger Click HOME icon in the Setting screen In Setting DATA LOGGING OFF Input Te...

Page 14: ...n go For step 2 If no check for the power input connections check whether the unit is getting proper supply at proper terminals Connecting the supply to the wrong terminals may damage the unit permane...

Reviews: