2-6
CheetahSwitch Workgroup-3616
Changing Speed and Flow Control
Use the Line Speed and Flow Control screen to set port speed or flow control as
shown in the following figure and table.
+------------------------------------------------------------------------------+
| ES3616 CheetahSwitch Workgroup-3616
switch_a
|
| ~ic Management/LAN Port Configurations/Line Speed & Flow Control
admin
|
+------------------------------------------------------------------------------+
+------------------------------------------------------------------+
|
Line Speed & Flow Control
|
+------------------------------------------------------------------+
| |All 10/100M Ports:
|
| |All 100M FX Ports: Speed-100M/FD FC-off
|
| |Port
1
(10/100M): Speed-100M/FD FC-off
|
| |Port
2
(100M FX): Speed-100M/FD FC-off
|
| |Port
3
(10/100M): Speed-Auto
FC-Auto
(100M/FD FC-Off)
|
| |Port
4
(10/100M): Speed-Auto
FC-Auto
(Down)
|
| |Port
5
(10/100M): Speed-Auto
FC-Auto
(Down)
|
| |Port
6
(10/100M): Speed-Auto
FC-Auto
(Down)
|
| |Port
7
(10/100M): Speed-Auto
FC-Auto
(Down)
|
| |Port
8
(10/100M): Speed-Auto
FC-Auto
(Down)
|
| |Port
9
(10/100M): Speed-Auto
FC-Auto
(Down)
|
| |Port 10
(10/100M): Speed-Auto
FC-Auto
(Down)
|
| |Port 11
(10/100M): Speed-Auto
FC-Auto
(Down)
|
|v|Port 12
(10/100M): Speed-Auto
FC-Auto
(Down)
|
+------------------------------------------------------------------+
--------------------------------------------------------------------------------
<UpArrow><DownArrow>Move
<Enter>Modify
<ESC>Previous
Parameter
Description
Port
Lists All 10/100M Ports, All 100M FX Ports, and individual Ports 1 - 16.
(Scroll to show all ports.)
Port Type
Displays port type as (10/100M) for RJ-45 ports, or (100M FX) for the fiber
modules.
Speed
Selects port speed as - Auto, 10M/HD, 10M/FD, 100M/HD or 100M/FD.
Flow Control
Selects flow control as - Auto, On or Off. When enabled, back pressure is
used for half duplex and IEEE 802.3x for full duplex. Flow control can
eliminate frame loss by "blocking" traffic from end stations or segments
connected directly to the switch when its buffers fill. Note that flow control
should not be used if a port is connected to a hub.
Status
For active connection: displays current status for each port, including
speed, duplex mode, and flow control.
For inactive connection: displays Down.