Getting Blood from a Site Other Than Your Fingertip

Capillary blood for blood sugar testing can be obtained, not only from 
the fingertips, but also from other sites (the palm, the forearm, the 
upper arm, the calf or the thigh), which is referred to as Alternative 
Site Testing (AST). We recommend palm as the non‑fingertip test site.

Use the clear ACCU‑CHEK Softclix Plus AST cap together with the 

ACCU‑CHEK Softclix Plus lancing device to collect blood from non‑
fingertip test sites.
Your ACCU‑CHEK Compact Plus system is designed to test blood 

 

glucose also from sites other than your fingertip. Please refer to the 

 

ACCU‑CHEK Compact test strip insert or your ACCU‑CHEK Compact 
Plus system’s owner’s booklet for specific blood glucose and AST 
testing instructions. 

IMPORTANT

 ‑ There is a delay (lag time) in the delivery of blood 

glucose to non‑fingertip sites when compared to fingertip. Therefore, 
there is a potential for a significant difference between fingertip and 
AST results. The length of delay (lag time), is strongly impacted by 
lifestyle, foods eaten, or any other event having impact on blood 
glucose levels. It is important that people considering non‑fingertip 
testing understand the following:

Talk to your doctor if you are considering testing on sites other 

 

 

than your fingertip.
AST testing is not recommended during periods of rapid 

 

 

decreases or increases in blood glucose levels.
AST testing is not recommended for people with a history of 

 

 

recurrent hypoglycemia, who suspect their blood glucose is 
extremely low, or who are unaware of hypoglycemic events.

Never

 

 

 ignore symptoms of high or low blood sugar.

Do not change your treatment based on one result.

 

 

If the AST reading does not match how you feel, perform a 

 

 

fingertip test to confirm your results. If your blood glucose still 
does not reflect the way you feel, contact your doctor. For more 

information on AST testing please contact ACCU‑CHEK Customer 

Care service center at 1‑800‑858‑8072.

Do 

not

 test blood from the forearm, the upper arm, the calf and the 

thigh:

up to two hours following a meal, when blood glucose values can 

 

 

change quickly

after exercise

 

 

if you have a temperature or if a medical condition is limiting your 

 

 

mobility, e.g. after breaking a leg or being confined to bed

during peak action time of short‑acting insulin (up to 

 

 

approximately 4 hours after the injection) or rapid‑acting insulin 
analogues (up to approximately 2 hours after the injection)
Remove the colored cap from the lancing device.

1. 

Insert a new lancet into the lancing device as described in the 

2. 

section “Performing a Fingerstick” of this package insert.
Attach the clear plastic AST cap. As with the colored cap, the 

3. 

locating notch in the cap must be directly aligned with the 
locating line on the lancing device. The AST cap must click into 
place.
Adjust the clear AST cap to the highest setting. 

4. 

Wash the non‑fingertip site with warm water and dry it thoroughly.

5. 

Prime the lancing device by pressing down the plunger all the 

6. 

way down until it stops. 
Press and hold the lancing device against the fleshy area on the 

7. 

chosen AST site. Press the release button again and continue to 
apply steady pressure to the site.
Perform a blood sugar test with your ACCU‑CHEK Compact Plus 

8. 

meter as instructed in the section “Running a Blood Sugar Test 
with Blood from Your Fingertip” of your ACCU‑CHEK Compact Plus 
system’s owner’s booklet.

Don’t be afraid to apply strong pressure to the area with the lancing 
device to get a good blood drop.

Caring For Your Lancing Device

Your lancing device requires very little care.

Keep it away from extreme temperatures.

 

 

Clean the outside of your lancing device regularly and always if 

 

 

any blood gets on it with 70 % isopropyl (rubbing) alcohol to keep 
it in good working condition. In addition, thoroughly wipe the 
inside of the cap using a cotton bud lightly moistened with the 70 
% isopropyl (rubbing) alcohol. After cleaning, allow the lancing 
device time to dry thoroughly. Never dip the lancing device or the 
caps (colored cap and clear AST cap) in cleaning liquid. Doing so 
may damage the internal parts of the lancing device so affecting 
its operation.
Do not dip the lancing device in liquid.

 

 

Do not use bleach to clean the lancing device or caps.

 

 

Also Available from Roche Diagnostics

ACCU‑CHEK Compact Plus System

ACCU‑CHEK Softclix Lancets 

100/box
200/box

ACCU‑CHEK Compact Test Strips

51/box
102/box

ACCU‑CHEK Compact Blue Control Solution

2 x 3 mL/box

Assistance Available

If you need assistance, please contact the ACCU‑CHEK Customer Care 

 

Service Center toll‑free, 24 hours a day, 7 days a week. We offer 

 

assistance in Spanish and many other languages.

1‑800‑858‑8072  phone
1‑800‑858‑8074  TDD/TYY (for hearing impaired)

One (1) Year Warranty

Roche warrants the ACCU‑CHEK Softclix Plus lancing device against 
defects in materials and workmanship for a period of one (1) year from 
the date of purchase. The liability of Roche under this warranty is 
limited to the repair or replacement, at Roche’s option, of all parts or 
materials proven to be defective. This warranty does not cover repair 
or replacement of ACCU‑CHEK Softclix Plus lancing devices which have 
been subjected to alteration, misuse, tampering, or abuse. 
THE FOREGOING WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES, 
WHETHER EXPRESS, IMPLIED, OR STATUTORY. ROCHE DISCLAIMS ANY 
AND ALL IMPLIED WARRANTIES, INCLUDING THE IMPLIED WARRANTIES 
OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. 
Roche’s entire liability with respect to the ACCU‑CHEK Softclix Plus 
 lancing device shall be the repair or replacement of nonconforming 
 devices, at Roche’s option. In no case shall Roche be liable for 
incidental, indirect, special, or consequeontial damages, so the above 
limitation and exclusion may not apply to you. This warranty gives you 
specific legal rights, and you may have other rights which vary from 
state to state. All inquiries about the ACCU‑CHEK Softclix Plus lancing 
device under the above warranty or service policy must be directed to 
ACCU‑CHEK Customer Care Service Center by calling 1‑800‑858‑8072.
You will be informed of the procedure necessary for replacement. 
Please DO NOT return any device to Roche without authorization.

IMPORTANT

 – Read carefully before use. Caution: A restricted license 

limits the use of this ACCU‑CHEK Softclix Plus lancing device in the 
United States.

The ACCU‑CHEK Softclix Plus lancing device and its use are protected 

by U.S. Patent Nos. Re.35,803; 6,419,661; 7,077,828; 7,322,998. 

 

A license to use the ACCU‑CHEK Softclix Plus lancing device is only 

granted when ACCU‑CHEK Softclix lancets are used with the 

ACCU‑CHEK Softclix Plus lancing device.

ACCU‑CHEK Softclix lancets are high precision components that are 

produced to the close tolerances required for satisfactory operation 

with the ACCU‑CHEK Softclix Plus lancing device. Use of other lancets 

with the ACCU‑CHEK Softclix Plus lancing device may prevent or impair 

proper function of the ACCU‑CHEK Softclix Plus lancing device.
Using the ACCU‑CHEK Softclix Plus lancing device indicates your 

acceptance of the restricted license to use the ACCU‑CHEK 

 

Softclix Plus lancing device only with ACCU‑CHEK Softclix lancets. 

Further, if you have purchased an ACCU‑CHEK Softclix Plus lancing 

device that includes this restricted license, then this restricted license 

applies regardless of any additional offers found in ACCU‑CHEK 

 

Softclix Plus lancing device packages. If you do not agree to the terms 

and conditions of the restricted license, you may return, at the place of 

purchase, the unused ACCU‑CHEK Softclix Plus lancing device for a full 

refund. If you have any questions, please call the ACCU‑CHEK 

Customer Care Service Center at 1‑800‑858‑8072.
Except where prohibited by statute, all warranties covering the 

ACCU‑CHEK Softclix Plus lancing device are voided by use of the 

ACCU‑CHEK Softclix Plus lancing device with any lancets other than 

ACCU‑CHEK Softclix lancets.

Visit our website at www.accu‑chek.com. 

This product is covered by the following U.S. Patents: 6,419,661; 

7,077,828; 7,322,998; 6,464,649 and Re. 35,803.

C

 

This product fulfils the requirements of Directive 

93/42/EEC on medical devices. 

0 5077524001(02) 

R1 (black)

R1/1 – pi_05077524001_02_EnUs_420x216 – Black

Reviews: