background image

EXS-210 STEREO MICROSCOPE 

ACCU-SCOPE

® 

MAINTENANCE 

Please remember to 

never

 

leave the microscope with eyepieces removed and always protect the 

microscope with the dust cover when not in use. 

SERVICE 

ACCU-SCOPE

®

 microscopes are precision instruments which require periodic servicing to keep them 

performing properly and to compensate for normal wear. A regular schedule of preventative maintenance 
by qualified service personnel is highly recommended. Your authorized ACCU-SCOPE

®

 distributor can 

arrange for this service. Should unexpected problems be experienced with your instrument, proceed as 
follows: 

1. Contact the ACCU-SCOPE

®

 distributor from whom you purchased the microscope. Some

problems can be resolved simply over the telephone.

2. If it is determined that the microscope should be returned to your ACCU-SCOPE

®

 distributor or to

ACCU-SCOPE

®

 for warranty repair, pack the instrument in its original Styrofoam shipping carton. If you

no longer have this carton, pack the microscope in a crush-resistant carton with a minimum of three
inches of a shock absorbing material surrounding it to prevent in-transit damage. The microscope should
be wrapped in a plastic bag to prevent Styrofoam dust from damaging the microscope. Always ship the
microscope in an upright position; 

NEVER SHIP A MICROSCOPE ON ITS SIDE

. The microscope or

component should be shipped prepaid and insured.

LIMITED MICROSCOPE WARRANTY 

This microscope and its electronic components are warranted to be free from defects in material and workmanship 
for a period of five years from the date of invoice to the original (end user) purchaser.   The LED lamp is warranted 
for a period of two years from the date of invoice to the original (end user) purchaser.  This warranty does not cover 
damage caused in-transit,  misuse, neglect, abuse or  damage resulting from improper servicing  or modification  by 
other  then  ACCU-SCOPE  approved  service  personnel.    This  warranty  does  not  cover  any  routine  maintenance 
work or any other work, which is reasonably expected to be performed by the purchaser. Normal wear is excluded 
from  this  warranty.  No  responsibility  is  assumed  for  unsatisfactory  operating  performance  due  to  environmental 
conditions  such  as  humidity,  dust,  corrosive  chemicals,  deposition  of  oil  or  other  foreign  matter,  spillage  or  other 
conditions  beyond  the  control  of  ACCU-SCOPE  INC.    This  warranty  expressly  excludes  any  liability  by  ACCU-
SCOPE INC. for consequential loss or damage on any grounds, such as (but not limited to) the non-availability to 
the End User of the product(s) under warranty or the need to repair work processes.  Should any defect in material, 
workmanship or electronic component occur under this warranty contact your ACCU-SCOPE distributor or ACCU-
SCOPE at (631) 864-1000.  This warranty is limited to the continental United States of America.  All items returned 
for warranty repair must be sent freight prepaid and insured to ACCU-SCOPE INC., 73 Mall Drive, Commack, NY  
11725 

– USA.  All warranty repairs will be returned freight prepaid to any destination within the continental United 

States  of  America,  for  all  foreign  warranty  repairs  return  freight  charges  are  the  responsibility  of  the 
individual/company who returned the merchandise for repair.  

ACCU-SCOPE is a registered trademark of ACCU-SCOPE INC., Commack, NY 11725 

Summary of Contents for EXS-210-24

Page 1: ...MANUAL EXS 210 STEREO MICROSCOPE SERIES 100 Lauman Lane Suite A Hicksville NY 11801 Tel 877 877 7274 Fax 516 801 2046 Email Info nyscopes com www microscopeinternational com LVWULEXWHG E...

Page 2: ...NT AND OPERATION CONNECTING THE POWER CORD 5 ADJUSTING INTERPUPILLARY DISTANCE 5 ADJUSTING THE DIOPTER 6 ADJUSTING THE FOCUSING TENSION 6 CHANGING THE MAGNIFICATION 7 ADJUSTING ILLUMINATION 7 OBSERVIN...

Page 3: ...semble any component including eyepieces objective housing or the focusing assembly 2 Keep the instrument clean remove dirt and debris regularly Accumulated dirt on metal surfaces should be cleaned wi...

Page 4: ...shipment UNPACKING AND COMPONENTS Your microscope arrived packed in a molded shipping carton Do not discard the carton the shipping carton should be retained for reshipment of your microscope if need...

Page 5: ...210 STEREO MICROSCOPE ACCU SCOPE 4 COMPONENTS DIAGRAM continued Indicent Top Illuminator Transmitted Bottom Illuminator Incident Top Illuminator Variable Intensity Adjustment Dial Power Cord Receptac...

Page 6: ...he way toward the front of the microscope or away from you for the Top illuminator the dial on the right side of the microscope should be turned all the way toward the back of the microscope or toward...

Page 7: ...e diopter ring on left eyepiece to focus the specimen NOTE The working distance of the microscope is 57mm the distance between the microscope objective to the top of the specimen Adjusting the Focusin...

Page 8: ...cation of eyepiece i e 3x X 10 30x Adjusting Illumination Fig 6 The EXS 210 is equipped with a rechargeable variable built in 3 way illumination system LEDs for incident top and transmitted bottom Bri...

Page 9: ...ion A slight turn of the focusing knobs may be needed to sharpen focus Recharging the Microscope Fig 8 The LED cordless rechargeable microscope is completely portable and be used indoors or outdoors i...

Page 10: ...able batteries 5 Close the trap door and place the microscope in an upright position 6 Plug the charger to the power receptacle on the back of the microscope and plug into an electrical receptacle for...

Page 11: ...Illumination system Adjustable illumination for both LEDs top and bottom OPTICAL DATA EYEPIECE OBJECTIVE 1X 2X 3X 4X 5X 22MM Total Magnification 5X 10X 15X 20X FOV mm 22 12 8 6 10X 20mm Total Magnifi...

Page 12: ...iopter adjustment is incomplete Complete diopter adjustment 2 Dirt is visible in field of view Dirt on specimen Clean specimen Dirt on eyepiece Clean eyepiece 3 The visibility of the image is poor Dus...

Page 13: ...m the date of invoice to the original end user purchaser The LED lamp is warranted for a period of two years from the date of invoice to the original end user purchaser This warranty does not cover da...

Reviews: