background image

EXS-210 STEREO MICROSCOPE 

ACCU-SCOPE

® 

2

SAFETY NOTES 

1. Open the shipping carton carefully to prevent any accessory, i.e. eyepieces, from dropping and being

damaged.

2. Keep the instrument out of direct sunlight, high temperature or humidity, and dusty environments.

3. If any specimen solutions or other liquids splash onto the stage, objective or any other component,

disconnect the power cord immediately and wipe up the spillage. Otherwise, the instrument may be
damaged.

4. 

LAMP REPLACEMENT -- CAUTION

:  the glass housing of the lamp may be extremely 

hot.  DO NOT attempt to change the lamp before it is completely cooled or without 
wearing adequate skin protection.   

5. All electrical connectors (power cord) should be inserted into an electrical surge protector to prevent

damage due to voltage fluctuations.

6. Confirm that the input voltage indicated on your microscope corresponds to your line voltage. The

use of a different input voltage other than indicated will cause severe damage to the microscope.
NOTE:  Always plug the microscope power cord into a suitable grounded electrical outlet.
Use only the AC adapter provided with the microscope.

CARE AND MAINTENANCE

1. Do not attempt to disassemble any component including eyepieces, objective housing or the focusing

assembly.

2. Keep the instrument clean; remove dirt and debris regularly. Accumulated dirt on metal surfaces

should be cleaned with a damp cloth. More persistent dirt should be removed using a mild soap
solution. Do not use organic solvents for cleansing.

3. The outer surface of the optics should be inspected and cleaned periodically using an air bulb. If dirt

remains on the optical surface, use a soft, lint free cloth or cotton swab dampened with a lens
cleaning solution (available at camera stores). All optical lenses should be swabbed using a circular
motion. A small amount of absorbent cotton wound on the end of a tapered stick makes a useful tool
for cleaning recessed optical surfaces. Avoid using an excessive amount of solvents as this may
cause problems with optical coatings or cemented optics or the flowing solvent may pick up grease
making cleaning more difficult.

4. Store the instrument in a cool, dry environment. Cover the microscope with the dust cover when not

in use.

5. ACCU-SCOPE

®

 microscopes are precision instruments which require periodic servicing to maintain

proper performance and to compensate for normal wear. A regular schedule of preventative
maintenance by qualified service personnel is highly recommended. Your authorized ACCU-SCOPE

® 

distributor can arrange for this service.

Summary of Contents for EXS-210-24

Page 1: ...MANUAL EXS 210 STEREO MICROSCOPE SERIES 100 Lauman Lane Suite A Hicksville NY 11801 Tel 877 877 7274 Fax 516 801 2046 Email Info nyscopes com www microscopeinternational com LVWULEXWHG E...

Page 2: ...NT AND OPERATION CONNECTING THE POWER CORD 5 ADJUSTING INTERPUPILLARY DISTANCE 5 ADJUSTING THE DIOPTER 6 ADJUSTING THE FOCUSING TENSION 6 CHANGING THE MAGNIFICATION 7 ADJUSTING ILLUMINATION 7 OBSERVIN...

Page 3: ...semble any component including eyepieces objective housing or the focusing assembly 2 Keep the instrument clean remove dirt and debris regularly Accumulated dirt on metal surfaces should be cleaned wi...

Page 4: ...shipment UNPACKING AND COMPONENTS Your microscope arrived packed in a molded shipping carton Do not discard the carton the shipping carton should be retained for reshipment of your microscope if need...

Page 5: ...210 STEREO MICROSCOPE ACCU SCOPE 4 COMPONENTS DIAGRAM continued Indicent Top Illuminator Transmitted Bottom Illuminator Incident Top Illuminator Variable Intensity Adjustment Dial Power Cord Receptac...

Page 6: ...he way toward the front of the microscope or away from you for the Top illuminator the dial on the right side of the microscope should be turned all the way toward the back of the microscope or toward...

Page 7: ...e diopter ring on left eyepiece to focus the specimen NOTE The working distance of the microscope is 57mm the distance between the microscope objective to the top of the specimen Adjusting the Focusin...

Page 8: ...cation of eyepiece i e 3x X 10 30x Adjusting Illumination Fig 6 The EXS 210 is equipped with a rechargeable variable built in 3 way illumination system LEDs for incident top and transmitted bottom Bri...

Page 9: ...ion A slight turn of the focusing knobs may be needed to sharpen focus Recharging the Microscope Fig 8 The LED cordless rechargeable microscope is completely portable and be used indoors or outdoors i...

Page 10: ...able batteries 5 Close the trap door and place the microscope in an upright position 6 Plug the charger to the power receptacle on the back of the microscope and plug into an electrical receptacle for...

Page 11: ...Illumination system Adjustable illumination for both LEDs top and bottom OPTICAL DATA EYEPIECE OBJECTIVE 1X 2X 3X 4X 5X 22MM Total Magnification 5X 10X 15X 20X FOV mm 22 12 8 6 10X 20mm Total Magnifi...

Page 12: ...iopter adjustment is incomplete Complete diopter adjustment 2 Dirt is visible in field of view Dirt on specimen Clean specimen Dirt on eyepiece Clean eyepiece 3 The visibility of the image is poor Dus...

Page 13: ...m the date of invoice to the original end user purchaser The LED lamp is warranted for a period of two years from the date of invoice to the original end user purchaser This warranty does not cover da...

Reviews: