EXS-210 STEREO MICROSCOPE 

ACCU-SCOPE

® 

5

ASSEMBLY

Your stereo microscope comes pre-assembled.  Optional eyeguards are included with your microscope 
and can be installed on the eyepieces to help block out extraneous light.   

ADJUSTMENT & OPERTATION 

Voltage Check 

Confirm that the input voltage indicated on the rear label of the 
microscope corresponds to your line voltage. The use of a 
different input voltage than indicated will cause severe damage 
to your microscope. 

Connecting the Power Cord

 (Fig. 1)

 

Make sure the ON/OFF (I/O) switch 

 is turned to the OFF (O) 

position.  With the microscope facing away from you, make sure 
the illuminators are turned off.   

To turn the illuminators off:  for the bottom illuminator 

– the dial 

on the left side of the microscope 

 

should be turned all the 

way toward the front of the microscope (or away from you); for 
the Top illuminator 

– the dial on the right side 

③ 

of the 

microscope should be turned all the way toward the back of the 
microscope (or toward you).   

Insert the power cord into the power receptacle on the back of 
the microscope 

; make sure the connection is snug. 

Plug the other end of the power cord into the power supply 
receptacle.  

Input: 100V

240V, 0.15A; 50/60Hz 

Output: 4.5V DC; 1000mA 

Adjusting Interpupillary Distance 

(Fig. 2)

 

Different users have different interpupillary distances (this 
distance is between the centers of pupils of each eye). When 
operators of the microscope change, it will be necessary to 
adjust interpupillary distance. 

While looking through the eyepieces, hold the left and right 
eyepiece tubes 

① 

of the binocular assembly

 

and adjust the 

eyepiece tubes by opening or closing them until the left and right 
fields of view coincide completely and you are able to see a 
complete circle.

Fig. 1 

① 

③ 

② 

④ 

Fig. 2 

Summary of Contents for EXS-210-24

Page 1: ...MANUAL EXS 210 STEREO MICROSCOPE SERIES 100 Lauman Lane Suite A Hicksville NY 11801 Tel 877 877 7274 Fax 516 801 2046 Email Info nyscopes com www microscopeinternational com LVWULEXWHG E...

Page 2: ...NT AND OPERATION CONNECTING THE POWER CORD 5 ADJUSTING INTERPUPILLARY DISTANCE 5 ADJUSTING THE DIOPTER 6 ADJUSTING THE FOCUSING TENSION 6 CHANGING THE MAGNIFICATION 7 ADJUSTING ILLUMINATION 7 OBSERVIN...

Page 3: ...semble any component including eyepieces objective housing or the focusing assembly 2 Keep the instrument clean remove dirt and debris regularly Accumulated dirt on metal surfaces should be cleaned wi...

Page 4: ...shipment UNPACKING AND COMPONENTS Your microscope arrived packed in a molded shipping carton Do not discard the carton the shipping carton should be retained for reshipment of your microscope if need...

Page 5: ...210 STEREO MICROSCOPE ACCU SCOPE 4 COMPONENTS DIAGRAM continued Indicent Top Illuminator Transmitted Bottom Illuminator Incident Top Illuminator Variable Intensity Adjustment Dial Power Cord Receptac...

Page 6: ...he way toward the front of the microscope or away from you for the Top illuminator the dial on the right side of the microscope should be turned all the way toward the back of the microscope or toward...

Page 7: ...e diopter ring on left eyepiece to focus the specimen NOTE The working distance of the microscope is 57mm the distance between the microscope objective to the top of the specimen Adjusting the Focusin...

Page 8: ...cation of eyepiece i e 3x X 10 30x Adjusting Illumination Fig 6 The EXS 210 is equipped with a rechargeable variable built in 3 way illumination system LEDs for incident top and transmitted bottom Bri...

Page 9: ...ion A slight turn of the focusing knobs may be needed to sharpen focus Recharging the Microscope Fig 8 The LED cordless rechargeable microscope is completely portable and be used indoors or outdoors i...

Page 10: ...able batteries 5 Close the trap door and place the microscope in an upright position 6 Plug the charger to the power receptacle on the back of the microscope and plug into an electrical receptacle for...

Page 11: ...Illumination system Adjustable illumination for both LEDs top and bottom OPTICAL DATA EYEPIECE OBJECTIVE 1X 2X 3X 4X 5X 22MM Total Magnification 5X 10X 15X 20X FOV mm 22 12 8 6 10X 20mm Total Magnifi...

Page 12: ...iopter adjustment is incomplete Complete diopter adjustment 2 Dirt is visible in field of view Dirt on specimen Clean specimen Dirt on eyepiece Clean eyepiece 3 The visibility of the image is poor Dus...

Page 13: ...m the date of invoice to the original end user purchaser The LED lamp is warranted for a period of two years from the date of invoice to the original end user purchaser This warranty does not cover da...

Reviews: