[.XX±0.130]
X±1.00°
2. TO KEEP DRAWING SIMPLER, CABLE SHIELDS ARE NOT SHOWN.
N/A
N/A
N/A
A
B
C
D
B
4
3
1
2
4
C
CONTROLLER/CLIENT/CLIENT W/TACH, AXIOM 400
INTERCONNECT DRAWING,
R
107481
DWG. NO.
[.X±0.500]
REV
2
NOTES:
1
SOLIDWORKS
NONE
CAD SYS.
DATE
B
SIZE
DATE
DATE
MECH ENG
11.06.04
11.06.04
11.06.04
DRAWN
CHKD
ENGR
DEPT.
CUSTOMER
TCS
RAD
RAD
E-
SCALE
CONTRACT #
TELFORD, PA 18969 USA
ACCU-SORT SYSTEMS, inc.
D
C
A
1
2
3
PART NO. 0107481000
.X±0.10°
1. TACHOMETER MUST BE CONFIGURED FOR NPN OPEN COLLECTOR OUTPUT.
SHEET
53830
INCH
DIMENSIONS ARE IN INCHES [MILLIMETERS]
OF
REMOVE SHARP EDGES AND BURRS
CAGE CODE
[.XXX±0.013]
FT.,IN ±1"
FRACTIONS ±1/4
UNLESS OTHERWISE SPECIFIED
2004 ACCU-SORT SYSTEMS, INC.
ANGULAR
1
THIS IS NOT A CONTROLLED COPY UNLESS
STAMPED “CONTROLLED COPY” IN RED
.XXXX±.0005
[METRIC]
THIS DOCUMENT IS PROVIDED FOR A
SPECIFIC PURPOSE AND THE DISCLOSED
INFORMATION REMAINS OUR PROPERTY.
IT MAY NOT BE DISCLOSED, COPIED,
OF THIS DOCUMENT.
APPEAR ON ANY COPY OR REPRODUCTION
PRIOR APPROVAL. THIS NOTICE MUST
SPECIFIC PURPOSE, WITHOUT ACCU-SORT’S
OR REPRODUCED, EXCEPT FOR THE
TOLERANCES:
ALL BEND RELIEFS TO SUIT
ALL C-CINKS ARE 82° INCLUDED ANGLE
ALL ANGLES ARE 90°
.XXX±.0050
[X±2.500]
.XX±0.01°
REVISION
BY
RAD/TCS
ECO
DATE
02.02.05
UPDATED
.XX±.0200
.X±.1000
APPLICATION EXAMPLE:
THREE UNIT CONTROLLER/CLIENT TRACKING
CONFIGURATION. THIS CONFIGURATION COULD BE
A X PATTERN TOP READ WITH A SINGLE FRONT READ
AXIOM. SERIAL PORT FROM CONTROLLER AXIOM
WILL TRANSMIT DATA FROM READ STATION TO
A SORTATION CONTROLLER. HOST PC ATTACHED TO
ETHERNET SWITCH COULD BE USED FOR DATA
COLLECTION. AXIOM DIAGNOSTIC AND CONFIGURATION
PC CAN BE USED TO MONITOR PERFORMANCE OF
INDIVIDUAL AXIOM SCANNERS IN READ STATION.
ALL 3 SCANNERS COULD BE MONITORED BY OPENING
3 INSTANCES OF ACCESS AND ATTACHING TO
THE IP ADDRESSES OF THE INDIVIDUAL SCANNERS
IN THE READ STATION.
RED
BLK
RED
AXIOM 400
CLIENT1
GND
TACH-
TACH+
V+
GND
V+
TRIG+
TRIG-
GND
TX1
TX2
RX1
RX2
TX+
TX-
RX+
RX-
V+
GND
POW
E
R
CONTROLLER
I/01+
I/02+
I/02-
R
E
L
AYS
1
&
2
I/03+
I/03-
I/04+
I/04-
R
E
L
AYS
3
&
4
V+
GND
POW
E
R
ET
HERNET
TA
C
H
TR
IGGER
SERI
A
L COM
GRN/WH
SET FOR NPN OPEN
TACHOMETER
HOST PC
COLLECTOR
NOTE: TACH MUST BE
PART # 105365001
V+
GND
POW
E
R
I/01+
I/01-
POW
E
R
I/02-
R
E
L
AYS
1
&
2
I/03+
I/03-
I/04+
I/04-
R
E
L
AYS
3
&
4
V+
GND
ET
HERNET
TX+
TX-
RX+
TA
C
H
GND
V+
TACH-
TACH+
RX-
I/01-
TR
IGGER
TRIG+
V+
GND
TRIG-
SERI
A
L COM
TX1
TX2
I/02+
BLK
CONTROLLER
RX2
ORG/WH
CLIENTS PER
AXIOM 400
PART # 105365001
RED
BLK
ORG
ORG/WH
GRN
GRN/WH
GND
40 WATT POWER SUPPLY
AXIOM 400
AXIOM 400
PART # 105365001
GRN/WH
GRN
ORG/WH
ORG
GRN
PART # 100019875
40 WATT POWER SUPPLY
CLIENT 2
GND
V+
GND
POW
E
R
I/01+
I/01-
I/02+
I/02-
R
E
L
AYS
1
&
2
I/03+
TACH+
I/04+
I/04-
R
E
L
AYS
3
&
4
GND
POW
E
R
SERI
A
L COM
TR
IGGER
TA
C
H
ET
HERNET
V+
V+
PHOTO EYE
TACH-
GND
TRIG-
V+
TRIG+
GND
TX1
TX2
RX1
RX2
TX+
TX-
RX+
RX-
PORT5
PORT4
RED
ORG
WHT
AXIOM 400
PORT3
I/03-
RX1
RED
AXIOM 400
RUNNING AXCESS
BLK
PORT2
CONFIGURATION PC
WHT
PORT1
AXIOM DIAGNOSTIC AND
40 WATT POWER SUPPLY
PART#1000020569
HOST RS232 PORT GND
HOST RS232 PORT RECEIVE
HOST RS232 PORT TRANSMIT
BLK
NOTE:
MAX. 5 AXIOM
AXIOM 400
CLIENT 5
LINKSYS
5-PORT
ETHERNET SWITCH
ASI # 1000059304
Summary of Contents for AXIOM 400
Page 1: ...AXIOM 400 Bar Code Scanning Solutions Product Manual...
Page 96: ...8 8 Service AXIOM 400 Product Manual Accu Sort Systems inc 08 AXIOM400 Service_R10 doc Notes...
Page 104: ...B 2 Read Charts AXIOM 400 Product Manual Accu Sort Systems inc A2 AXIOM400 ReadCharts_R10 doc...
Page 105: ...AXIOM 400 Product Manual Read Charts B 3 A2 AXIOM400 ReadCharts_R10 doc Accu Sort Systems inc...
Page 106: ...B 4 Read Charts AXIOM 400 Product Manual Accu Sort Systems inc A2 AXIOM400 ReadCharts_R10 doc...
Page 107: ...AXIOM 400 Product Manual Read Charts B 5 A2 AXIOM400 ReadCharts_R10 doc Accu Sort Systems inc...