AXIOM™ 400 Product Manual
Electrical Installation
4-3
04-AXIOM400-Electrical_Installation_R10.doc
Accu-Sort Systems, inc.
General Electrical Installation Guidelines and Precautions
It is important that you follow these general precautions when installing,
setting up, operating, maintaining, troubleshooting or replacing any Accu-Sort
products, parts or related equipment.
CAUTION
: The Axiom uses Class 3R lasers IEC, (Class II CDRH). Avoid staring
at the laser light source. While laser light does not constitute a health hazard,
staring at the laser for prolonged periods could result in eye damage.
As you plan and install your Axiom bar code solution application, be sure to
keep the following guidelines in mind:
Determine the reader is in the proper orientation and position as outlined
in Chapter 3.
Leave adequate clearances (approximately 8-12 inches) for wiring.
The wiring base has four conduit openings. Seal unused openings. Use cord
grips with rubber grommets on cables that enter the wiring base.
Route wires carefully to reduce or minimize electrical noise. When power
and communication wiring must cross, make their intersection
perpendicular.
Proper grounding of the wiring base limits the effects of noise due to
Electromagnetic Interference (EMI).
Summary of Contents for AXIOM 400
Page 1: ...AXIOM 400 Bar Code Scanning Solutions Product Manual...
Page 96: ...8 8 Service AXIOM 400 Product Manual Accu Sort Systems inc 08 AXIOM400 Service_R10 doc Notes...
Page 104: ...B 2 Read Charts AXIOM 400 Product Manual Accu Sort Systems inc A2 AXIOM400 ReadCharts_R10 doc...
Page 105: ...AXIOM 400 Product Manual Read Charts B 3 A2 AXIOM400 ReadCharts_R10 doc Accu Sort Systems inc...
Page 106: ...B 4 Read Charts AXIOM 400 Product Manual Accu Sort Systems inc A2 AXIOM400 ReadCharts_R10 doc...
Page 107: ...AXIOM 400 Product Manual Read Charts B 5 A2 AXIOM400 ReadCharts_R10 doc Accu Sort Systems inc...