4-12
Electrical Installation
AXIOM™ 400 Product Manual
Accu-Sort Systems, inc.
04-AXIOM400-Electrical_Installation_R10.doc
Tachometer Connections
In applications where product tracking is required, a tachometer is typically
used. Connect the tachometer wiring to the wiring base terminal blocks.
(See Figure 4-9.)
Figure 4-9
: Wiring Tachometer Input to Axiom Wiring Base
When a tachometer is required, Accu-Sort tachometer (PN 1000019875) is
recommended. Wire this tachometer as indicated in shaded area of Table 4-3.
(Wire colors indicated for standard NPN Output, shown in shaded areas.)
Table 4-3
: Tachometer Wiring
TACH WIRE COLOR
TERM
NPN OUTPUT
PNP OUTPUT
24V
WHT/ORG
V +
Supply Voltage
Supply Voltage
(Jumper to V+)
TACH +
Jumper to V+
Tach Output
+ Output
WHT/BLU
TACH -
Tach Output
Jumper to GND
- Output
BLU/WHT+ORG/WHT
GND
Common Common
The shielding for the tachometer wiring MUST be terminated to earth ground.
(See Figure 4-10.)
Otherwise, belt static could result in a system failure.
Figure 4-10
:
Tachometer Shielding Terminated to Earth Ground
If your application uses a tachometer other than the one available from Accu-
Sort, follow the TACH wiring table to assure proper wiring.
Multiple Readers
When an application incorporates multiple readers wire
the tachometer to the Axiom Controller.
(Reference drawings 107480 and
107481 in Appendix D.)
Summary of Contents for AXIOM 400
Page 1: ...AXIOM 400 Bar Code Scanning Solutions Product Manual...
Page 96: ...8 8 Service AXIOM 400 Product Manual Accu Sort Systems inc 08 AXIOM400 Service_R10 doc Notes...
Page 104: ...B 2 Read Charts AXIOM 400 Product Manual Accu Sort Systems inc A2 AXIOM400 ReadCharts_R10 doc...
Page 105: ...AXIOM 400 Product Manual Read Charts B 3 A2 AXIOM400 ReadCharts_R10 doc Accu Sort Systems inc...
Page 106: ...B 4 Read Charts AXIOM 400 Product Manual Accu Sort Systems inc A2 AXIOM400 ReadCharts_R10 doc...
Page 107: ...AXIOM 400 Product Manual Read Charts B 5 A2 AXIOM400 ReadCharts_R10 doc Accu Sort Systems inc...