AXIOM™ 400 Product Manual
Setup and Operations
5-7
05-AXIOM400-Setup_and_Operations_R10.doc
Accu-Sort Systems, inc.
Standalone Operation
In a typical standalone setup, a single Axiom scans bar codes on one side of
packages as they move down a conveyor. A photoeye is used to trigger the
Axiom to begin searching for valid bar codes. Bar code data is transmitted to a
host device.
Figure 5-4:
Typical Single-Unit Axiom Application
A simplified schematic diagram of the required items is shown below:
2
4
3
1
AXIOM Wiring Base
PN 0104636001 (US)
PN 0104636002 (Metric)
AXIOM
Scan Head
(4 options available)
Photoeye
PN 1000020569
Network/Host
Communications
PC
Universal Mounting
Bracket
PN 0105307002
Programming Cable
PN 1000007308
Power Supply
PN 0105365001 (120V)
PN 0105365002 (240V)
AC Power
Figure 5-5:
Schematic Diagram of Typical Single-Unit Axiom Installation