Accu-Steam™ G2 Gas Service Manual
PAGE 20
SP8042-1609
Parts Identification, Removal and Installation
Flame Sensor
AT2E-4717-1
Igniter
AT2E-4716-1
Infrared Burner
AT2B-2099-2
1. Unplug from wall receptacle.
2. Lower front access panel by removing the
screws in the upper corners of the panel.
3.
Remove orange flame sense wire.
4.
Remove screws and flame sensor
5. Reinstall in reverse order.
1. Unplug from wall receptacle.
2. Lower front access panel by removing the
screws in the upper corners of the panel.
3. Remove igniter wire
4. Remove screws and igniter
5. Reinstall in reverse order.
6. Set new igniter gap between 1/8”-3/16’’
1. Unplug from wall receptacle.
2. Turn off gas supply and disconnect the unit from
supply hose.
3. Remove gas line at venture
4. Remove front 2 nuts fully and loosen back 2
nuts securing burner
5. Remove Burner
6. Reinstall in reverse order.
Note: When diagnosing a bad burner, often
times the exterior back side of the burner will
have black or gray discoloration in a circular
or half moon shaped
pattern.