Accu-Steam™ G2 Gas Service Manual
PAGE 21
SP8042-1609
Parts Identification, Removal and Installation
Temperature Sensor, 1000 Ω RTD
AT0E-2885-8 (Black heat shrink)
1. Unplug from wall receptacle.
2. Lower front access panel by removing the screws in
the upper corners of the panel.
3. Locate and remove RTD wires attached to the main
control board .
4. Remove nut securing RTD to griddle .
5. Reinstall in reverse order.
Hi-Limit Sensor, 100 Ω RTD
AT0E-2885-7 (Red heat shrink)
1. Unplug from wall receptacle.
2. Lower front access panel by removing the screws
in the upper corners of the panel.
3. Locate and remove RTD wires attached to the Hi-
Limit control Board.
4. Remove nut securing RTD to griddle .
5. Reinstall in reverse order.
RTD Resistance Chart
RTD Testing
Temp
Hi-Limit Sensor
(100 Ohm)
Temp Sensor
(1k Ohm)
Temp
Hi-Limit Sensor
(100 Ohm)
Temp Sensor
(1k Ohm)
70
108.22
1082.25
100
114.68
1146.82
300
156.91
1569.10
125
120.03
1200.38
325
162.08
1620.88
150
125.37
1253.72
350
167.24
1672.44
175
130.68
1306.84
375
172.37
1723.77
200
135.97
1359.74
400
177.48
1774.89
225
141.24
1412.41
425
182.57
1825.78
250
146.48
1464.86
450
187.64
1876.45
275
151.7
1517.09
475
192.68
1926.89
NOTICE: Failure to unplug the unit before
pulling wires from the board could result in
fatal damage to the control board.