Accu-Steam™ Gas G2 Installation and Operators Manual
MP5017-1702
PAGE 20
INSTALLATION
Use a spirit level resting on the appliance cooking
surface to ensure it is level front-to-back and left-
to-right.
TABLE TOP
Install the (4) rubber foot tips provided with your
appliance onto the four foot adjusters of each
of the commercial appliance legs. This will keep
the griddle from sliding on the counter-top under
normal use. Once the rubber foot tips have been
installed, adjust the four foot adjusters up or
down as needed to level the griddle side to side
and front to back.
ACCUTEMP STAND
If on an AccuTemp griddle stand with casters,
ensure that the floor surface is level and place
the two locking casters to the “on” position
and follow the leveling instructions to verify the
appliance is level.
ELECTRICAL SUPPLY
The ACCU-STEAM™ griddle has been designed,
manufactured and tested to meet or exceed the
demanding standards of safety set forth by
ANSI
Z83.11.
To to ensure that this high level of safety
is maintained in your installation, it is important
that you read and understand the following
information before attempting to plug in your
griddle.
ELECTRICAL REQUIREMENTS
Electrical requirements are listed on the data
plate located on the front right of the control
panel. All standard AccuTemp griddles are
supplied with a 6ft (1.83m) cord and the
appropriate UL listed plug that must be connected
to a 15 Amp (120Vac) or a 20 Amp (208-240Vac)
depending on the rating listed on the data
plate. Make sure that the voltage at your supply
receptacle is within ± 10 % of the voltage listed
on the griddle data plate. Connection to any other
voltage may cause damage to components in the
commercial appliance. The appliance plug must
be used with the appropriate receptacle.
Direct wiring will void the warranty.
GROUNDING INSTRUCTIONS
Grounding provides a path for electric current to
reduce the risk of shock. This product is equipped
with a power cord having a grounding conductor
and a grounding plug. The plug must be plugged
into a grounded receptacle that is installed and
grounded in accordance with local codes, or in
the absence of local codes, with the
National
Electric Code, NFPA 70, or the Canadian
Electrical Code, CSA22.2
, as applicable.
Under no circumstances shall the grounding
or prong of the plug be cut off or bent to fit a
receptacle other than the one supplied. Do not
use any adapters to fit the receptacle.
GAS CONNECTION
This appliance has been manufactured for use
with the type of gas indicated on the data plate.
(See Fig. 3) If the locations gas supply does not
match the gas indicated on the equipment data
plate. Contact AccuTemp Products Technical
Service at (800) 480-0415
All gas connectors must be in accordance with
the local code, State and
National Fuel Federal
Gas Codes, ANSI Z223.1
The equipment should have a separate gas
shutoff valve (not supplied) installed in the
equipment supply line. A 1/2” inside diameter
or larger gas supply line or an
ANSI
approved
commercial flexible gas hose that the inside
diameter is 1/2” or larger this to insure adequate
volume of gas for the equipment. The facility
supply manifold and regulator must be sized to
the load of all the appliances connected to it.
If other appliances are connected to the same
supply line as this equipment the gas load must
When this appliance is installed with casters
it must be installed with the casters supplied.
A connector complying with either ANSI
Z21.69 - CSA 6.9. It must also be installed with
restraining means to the connector as specified
in the appliance manufacturer’s instructions.
WARNING
Summary of Contents for GG24A
Page 2: ......
Page 4: ......
Page 6: ......
Page 10: ......
Page 14: ......
Page 16: ......
Page 29: ...Accu Steam Gas G2 Installation and Operators Manual MP5017 1702 PAGE 22 OPERATION ...
Page 50: ......
Page 54: ......
Page 55: ...Accu Steam Gas G2 Installation and Operators Manual MP5017 1702 PAGE 46 NOTES ...
Page 56: ......