Maintenance 

Clean the Check Valve and Float Valve at least every 4-6 months, or as 
needed, to remove scale or debris 

 

Winterizing 

1.  Clean chlorination system following instructions below. 
2.  Close inlet isolation valve and operate pump until no more water can be  
      pumped out.   
3.   Shut system down and close the outlet isolation valve. 
4.   Siphon any remaining water from the solution tank. 
5.  Remove any debris from the chlorinator or solution tank. 
6.  Open the bottom drain on the pump. 
7.  Drain water from feed and discharge lines. 
8.  Make sure no water remains in the pump, chlorinator, pipe line, or solution    
     tank to prevent freezing over the winter. 

System Cleaning  

    Over time the chlorination system may develop a build-up of scale.  This   
     should be cleaned on a periodic basis, up to twice per year.  If scale formation  
     is severe, more frequent cleanings may be necessary.  Cleaning may be            
     accomplished by soaking the chlorinator with a dilute acid solution according   
     to the instructions below. 
 

NOTE: Addition of muriatic acid may lower the pH of the pool water

 

 

Preparation for cleaning 

1.  Prepare 2 gallons of muriatic acid. 
2. 

Always use

 appropriate safety equipment while servicing the unit or handling 

chemicals. 

3.  Clean the feeder in a well-ventilated area.  Chlorine gas may be released dur-

ing the cleaning process! 

Cleaning procedure

 

1.  Turn system off. 
2.  Open lid and remove all tablets.  Use proper protective equipment when han-

dling chemicals. 

3.  Switch system on to begin flushing the system.   
4.  Wash out the feeder with a hose to remove remnants of tablets and loosen 

scale. 

Summary of Contents for PowerBase 3070AT

Page 1: ...ets only Do not mix Cal Hypo tablets with stabilized chlorine or bromine products or other sanitizing chemicals Fire or explosion could result Rev 04 26 10 NSF 50 The PowerBase 3070AT Chlorinator is N...

Page 2: ...or use ONLY with PPG Accu Tab Blue SI tablets utilizing the PPG patented erosion feeder technology that erodes only the bottom layer of tablets on the sieve plate while keeping tablets above the sieve...

Page 3: ...e chlorine application point with 1 1 2 PVC pipe or hose Include an isolation valve in the line 9 Plug the power cord into an 110v receptacle 10 If a chemical controller is utilized plug the controlle...

Page 4: ...4...

Page 5: ...maximum inlet flow is determined 6 Adjust flow through feeder using the discharge gate valve The chlorine delivery is determined by the flow rate through the chlorinator Use the graph above to determ...

Page 6: ...on system may develop a build up of scale This should be cleaned on a periodic basis up to twice per year If scale formation is severe more frequent cleanings may be necessary Cleaning may be accompli...

Page 7: ...hrough the blue tubing Circulate for 10 minutes 10 Open all valves to begin purging acid from system 11 Wash the walls and sieve plate of the feeder with a hose to remove all acid residue Chlorine gas...

Page 8: ...8 Electrical Drawing Base System...

Page 9: ...mpers between Terminal 1 4 Terminal 2 6 Electrical Drawing With HHL Pump Switch If a chemical controller is NOT used with the HHL Pump Switch the jumpers should be placed between Terminals 1 and 4 Ter...

Page 10: ...talled and operated and maintained in accordance with this manual and the instructions ac companying the System iii you at your cost promptly return the System or defective part to such location as ma...

Page 11: ...11...

Reviews: