- Instruction Manual for ESS R050100-
35
Note:
(a)
As default, Back-Up Supply function stays ON. If you want have power supply function on Back-Up
side (on-grid or off-grid), this function
③
should always be ON.
(b)
As default, Off-Grid Output Switch function stays OFF. If need power supply during utility outage,
this function
④
should also turn ON. This function works only if “Back-Up Supply” function is ON.
(c)
Off-Grid Output Switch will stay activated after first time being turned ON, unless the inverter is
rebooted.
(d)
The maximum SOC protection depth can only be set to 90% regardless of whether the SOC
protection switch is turned on.
4.3 Battery Status Display
The power indicator of the device (as shown on the right, the color of the indicator is subject
to the actual situation), the specific function description is shown in the following table:
①
②
③
④
⑤
⑥
⑦