background image

 

 

1. Safety Instructions 

 

 

Warning 

 

Do not use this product in areas where it may be exposed to water or other 

liquids. 

 

Unplug this product from the electric outlet before cleaning. Do not use liquid 

or aerosol cleaners. To clean, use a damp cloth. 

 

To reduce the risk of electric shock, do not disassemble this product. Take 

it to qualified service personnel when service or repair work is required. 

Opening or removing covers may expose you to dangerous voltages or other 

risks. Incorrect reassembly can cause electric shock when the appliance is 

subsequently used. 

 

Only use the cable provided with the unit. The use of other cables may result 

in electric shock, fire, or cause serious damage to the unit. 

 

Do not operate the unit in areas with high temperature or high humidity since it 

may prevent it from working correctly. 

 

 Caution 

 

When unplugging the power cord, do not pull it by the cord, but rather grip the 

plug to pull it out. Not following these instructions may result in electric shock, 

fire, or damage to the unit. 

 

Do not use the unit if the power cord is damaged or if the plug socket contact is 

loose. Not following these instructions may result in electric shock, fire, or 

other hazards. 

 

Do not place heavy objects over the cord and do not bend it excessively since 

it could get damaged. Not following these instructions may result in electric 

shock, fire, or other hazards. 

 

When not using the unit for a long time, remove the power plug from the electric 

outlet. 

 

 

 

Summary of Contents for AB5200

Page 1: ...1 AB5200 Bank Teller Bill Counter USER GUIDE www AccuBANKER com...

Page 2: ...Thank you for trusting AccuBANKER with your cash handling needs In order to optimize the performance of your equipment we encourage you to thoroughly read this user guide prior to use...

Page 3: ...pment Overview 9 4 1 Control Panel Description 9 4 2 Sensitivity Adjustment of the Counterfeit detection functions 11 5 Operation 12 5 1 Counting Operation 12 5 2 Miscounting errors 13 5 3 Setting the...

Page 4: ...ures this model offers are a Includes an external display that allows the client to visualize the operation b Automatic dust cover protects the operator during the unit s operation c Variable counting...

Page 5: ...y result in electric shock fire or cause serious damage to the unit Do not operate the unit in areas with high temperature or high humidity sinceit may prevent it from working correctly Caution When u...

Page 6: ...ll liquids of any kind on the product Unplug this product from the wall outlet and refer servicing to qualified service personnel under the following conditions When the power supply cord or plug is d...

Page 7: ...ace and make sure it is clean flat and leveled The unit should never be placed near or over a radiator heater register or close to a strong source of light Voltage operation range 100 240VAC 60 50 Hz...

Page 8: ...ed or damaged bills B Check for foreign objects mixed up with the bills such as paper clips rubber bands pieces of paper etc C If counting new bills fan them lightly since they often stick together D...

Page 9: ...ll stop counting in case a bill is considered suspicious The MG sensitivity can be adjusted by the user from 1 9 DD Bill Size Verification Width On Off This function allows the unit to analyze the siz...

Page 10: ...n use keys to set up the desired manual batch quantity Also used to adjust the counting functions as well as the Sensitivity of the counterfeit detection functions BATCH Preset batch selection By pres...

Page 11: ...l the display shows the current value for the selected function Next proceed to INCREASE or DECREASE the current value using the keys until reaching the desired sensitivity value Press START to valida...

Page 12: ...ROR MESSAGES section to solve the problem Select the desired verification functions to use MG UV DD based on the security features encountered on your currency Set up the rest of the options like SPEE...

Page 13: ...consider reducing them in case the sensitivity is too high 5 3 Setting the unit up for counting Polymer bills Press and hold the ADD key and turn the unit ON The unit will boot up in the Settings Men...

Page 14: ...oth counting as well as a trouble free operation Trial and error attempts are recommended before you make the final adjustment a For new thinner bills adjust toward to reduce the gap b For used thicke...

Page 15: ...justment knob Verify the bill s fitness quality dbL Two or more bills passedtogether Fan the bills Adjust thickness adjustment knob ddE Check the size of the bill width Verify the specific bill Reduce...

Page 16: ...s condition Stacker Capacity 200 bills good fitness condition Banknote size range 4 53 x 1 97 6 70 x 3 35 in Display High Resolution LCD Display Power Source 100 240 VAC 60 50 Hz Power Consumption 50...

Page 17: ...AccuBANKER USA 7104 NW 50th St Miami FL 33166 9AM 5PM ET Monday through Friday www AccuBANKER com Please give us a call at 1 888 993 2228...