5. Unit Maintenance (continued)
5.2 CIS Calibration Procedure
Proceed with the CIS calibration procedure when the machine is rejecting
many bills with NOT RECOGNIZED error message. It is highly
recommended to clean the machine first to make sure the CIS sensors are
cleaned. Also, after installing any new firmware update it is recommended to
calibrate the CIS sensors.
a.
Get ready the calibration plastic card included with the machine.
b.
Press
BATCH -1-2-3-6 START
to access the calibration menu. Then
press the #1 key to select “Adjust CIS”.
c.
Open the back cover and place the calibration card holding it from the top
rollers.
d.
Close the back cover then press START to begin the calibration process.
e.
Wait until the machine shows the message “
CIS Check – OK
”.
f.
Then proceed to press the #2 key “Adjust Count” then press START
g.
Wait for the message “
IR Check – OK
”.
h.
Press BACK to leave the calibration menu then proceed to remove the
calibration card inside the machine.
NOTE:
For a video reference of this procedure access our website support
page
www.accubanker.com/pages/support