background image

10 

 

Unpacking, etc.

 

• 

After removing the packing materials, check the appearance of the dispenser for possible defects or 
irregularities. If the product shows any irregularity in its appearance, contact the distributor.

 

• 

All the packing materials (straps, box, Styrofoam, wood, etc.) should never be left within the reach of 
children and should be disposed of according to local regulations.

 

• 

For safety, the product should be installed and used with caution in accordance with the User’s 
manual.

 

• 

Incorrect installation or careless use of the product may damage or injure the environment, humans, 
animals, and/or materials and property. The manufacturer does not bear any responsibility for the 
aforesaid damage or injury.

 

•  The dispenser performs best at room temperature of 50~75°F and a supply of water at 50°F.  

• 

The dispenser should only be installed indoors and should NOT be installed near heat generators such as heaters, 
stoves, or dishwashers

  

Product Installation

 

Where there is 

no heat source

 

Install in a place where there is no heating device 

such as a fireplace or a gas range and do not install in an 

area outside the range of 10 ~ 38 

/50 ~100

o

F. 

 

Allow 

enough ventilation 

• 

For normal operation, install the dispenser at least 4 

inches away from the back wall and 6 inches above the top 
of the dispenser. 

 

Never block the upper vents and do not place any 

load on it. 
• 

Poor ventilation will decrease the unit’s ability to 

make ice. 

 

 

 

Install on 

a flat 

surface 

 

Unstable installation may cause vibration and noise. 

The recommended angle of installation is 1

o

 

 

• 

A flat surface is recommended because there is a 

possibility that the product will fall and cause injury when 
the installation is made in a sloping place. 

 

• 

Installation should be indoors in a clean place 

• 

The drain hose should be installed at an angle so that drainage is good. 

• 

During installation and use, water leakage may occur due to various reasons. It must be used at a 

place where drainage facilities are fully equipped 

• 

When installing the product indoors (places such as living room, store, the floor where damage 

may occur due to leakage), please install natural drainage facilities and waterproof the floor. 

• 

Even when installing in the kitchen, a drain hole must be provided, and a drain hose must be 

connected. 
• 

The manufacturer shall not be held responsible for the spreading damage caused by insufficient 

drainage facilities in case of the above-mentioned problems and problems due to water supply hose 
deviation or breakage. 

 

Summary of Contents for AIWD160

Page 1: ...450 User s Manual BEFORE USE PLEASE READ AND FOLLOW ALL SAFETY RULES AND OPERATING INSTRUCTIONS FELIX STORCH INC Summit Appliance Division An ISO 9001 2015 registered company 770 Garrison Avenue Bronx...

Page 2: ...tart the product 15 17 Button operation 15 Function button description FND display window 16 Three drainage functions forced drainage automatic draining water drainage 17 Stop switch 17 Product Mainte...

Page 3: ...h CAUTION means that failure to heed this safety statement may result in minor or moderate personal injury or property or equipment damage What you must obey Prohibited Disassembly Prohibited No Conta...

Page 4: ...or disconnect power before cleaning or servicing Failure to do so can result in electrical shock or death Do not attempt to repair or replace any part of your ice dispenser unless it is specifically r...

Page 5: ...g the power cord to stop operation If you continue operating in abnormal conditions there is a risk of fire or electric shock Do not use Do not use if the outlet is loose or has a problem There is a r...

Page 6: ...SIG 193 PSIG 150 PSIG Compressor LRA 40A LRA 20A LRA 53A Fan Motor 115 V 0 7 A 115 V 1 1A 115 V 0 2A Geared Motor 115V 1 6A 115V 1 6A 115V 1 6A Maximum Fuse Size 20A 15A 20A Max HACR Breaker USA Only...

Page 7: ...7 Location of Parts AIWD282 SCIWD282 Front Top Bottom...

Page 8: ...8 Location of Parts AIWD450 Front Rear Top Bottom...

Page 9: ...9 Location of Parts AIWD160 Front Rear Top Bottom...

Page 10: ...F Allow enough ventilation For normal operation install the dispenser at least 4 inches away from the back wall and 6 inches above the top of the dispenser Never block the upper vents and do not plac...

Page 11: ...re chemically combined with water molecules These impurities are called dissolved solids The mineral content of the ice produced by the dispenser is reduced compared to the content in the water before...

Page 12: ...to make sure the outlet is properly grounded When a standard 2 prong wall outlet is encountered it is your responsibility and obligation to have it replaced with a properly grounded 3 prong wall outl...

Page 13: ...the lower set screws of the drain box then loosen the set screws on the top of the front panel and pull out the front panel taking both sides 3 Side panel Open the door loosen the screws on the top of...

Page 14: ...oduct as shown in the picture and secure the clip to prevent hose detachment After the installation is complete please operate the product and check whether there is leakage in the water supply and dr...

Page 15: ...sappear when restarting after the action against the ERROR Service cycle setting notification parts check replacement cycle notification If the motor is running for more than 10 000 hours the correspo...

Page 16: ...KING switch is operated FND 1st 2nd digits drain time 2 seconds oF 9 seconds Set Unit of one second FND 3rd 4th digits drain interval 1 0 hour 0 5 9 5 hours every 30 minutes F 6 ICE WATER volume contr...

Page 17: ...n interval 1 0 hour 0 5 to 9 5 hours every 30 minutes Initial water draining function F 4 Turn the power switch off and then on again the ICE MAKING OFF WASH switch at ICE MAKING position to operate t...

Page 18: ...at the same time for 3 seconds with any signal on the FND window Forced drainage will be done for 30 seconds 2 Turn off the power switch and disconnect the power plug from the outlet 3 Remove the uppe...

Page 19: ...o not touch or disassemble the parts of the ice maker Before service Turn off the power switch of the dispenser and the earth leakage breaker and disconnect the power plug from the outlet Choking haza...

Page 20: ...seal bolt 1 Check for leaks around the seal bolt Tighten if necessary and replace O rings 2 Always replace the O ring when loosening the seal bolt and tighten it again If there is no O ring apply Loc...

Page 21: ...eel and rust generated in contact with stainless steel and ordinary iron products during storage It should be removed with neutral detergent at the first sign of rusting If the rusting state is furthe...

Page 22: ...er Clean the level sensor with washing solution Wash the water level sensor thoroughly with clean water Fix the level sensor to the correct position 9 Switch the ICE MAKING OFF WASH switch to the ICE...

Page 23: ...MAKING OFF WASH switch to the WASH position and let the remaining water drain out for 5 minutes 13 Turn the power switch to OFF and disconnect the power plug from the outlet Disinfection procedure fi...

Page 24: ...24 Circuit Diagrams AIWD282 SCIWD282 AIWD450...

Page 25: ...25 Circuit Diagrams AIWD160...

Page 26: ...or Displayed when temperature sensor is open or shorted Check sensor and attachment abnormality Start operation after sensor part repair Stop ice making Er07 Temperature Sensor Error Occurs when the t...

Page 27: ...op ice making Er20 Cover error When the outlet cover is open Cover closed Operation after action Stop dispensing Er25 Motor restraint Occurs when Evaporator inlet outlet temperature is 18 or less for...

Page 28: ...28 NOTES...

Page 29: ...4 Is the water supply valve operating After confirming contact A S center 3 Ice freezes too late 1 Machine is too dirty lots of dust Air cooled After removing the front cover remove the dust net to t...

Page 30: ...t approved bywarrantor 4 Replacement parts or repair labor costs for units operated outside the United States 5 Repairs to parts or systems resulting from unauthorized modifications made to the applia...