SUPPLIED ACCESSORIES:

HOW TO USE THE PARTS COUNTING FEATURE

1) To set your balance to parts counting mode, scroll through the

weighing modes by pressing the CAL/MODE keypad until a down
facing arrow appears in the lower left corner on the display.  The
minimum parts quantity number (5) will also be displayed as a
flashing number.

2) Continue to press the CAL/MODE keypad to select the desired

parts counting unit: 5, 10, 25, 50 pieces.  After "50" is dis-
played, the indicator will scroll back to the gram weighing mode.

3) With the selected parts counting unit still flashing, place the

desired sample on the weighing pan.  Allow the sample to stabilize
for 3-5 seconds then press  OFF.  The parts counting function is now
set for the selected 5, 10, 25, 50 piece quantity.

IMPORTANT: Minimum individual (1 piece) part weight must be
greater than or equal to 5X "D" ("D" is the division or graduation of
the balance).  If the sample unit weight for one piece is less than 5X
"D" the display will read "Er 1", indicating that the individual 
(1 piece) part weight is too low and must be increased.  To reset,
press CAL/MODE and scroll through the weighing modes again to the
desired parts counting value.  Refer to the following chart for mini-
mum unit part weight (1 piece) for your particular balance.

B

alance

 

G

raduation

 

P

art

 W

eight

M

inimum

 (1 

piece

)

SV-30

0.005 kg

0.025 kg

SV-50

0.01 kg

0.05 kg

SV-100

0.02 kg

0.1 kg

AC Adapter

#AC-1 -For use in USA/Canada (AC 120V  60Hz)
#AC-2 -For use in Europe (AC 230V  50Hz)
#AC-3 -For use in U.K. (AC 240V  50Hz)
#AC-4 -For use in Japan (AC 100V  50/60Hz)
#AC-5 -For use in AUS/NZ (AC 240V  50Hz)

MINIMUM WEIGHING LIMITATION:  

Because the SV-Series is designed to be a heavy capacity balance,
minimal initial loads may not produce a response from the balance.
The minimum initial increment applied to each model should be 50
grams or more. Initial weighing loads may not produce the minimum
excitation voltage to produce weight readings. 

Instruction

Manual

PLEASE READ COMPLETE INSTRUCTIONS BEFORE USE

Platform

LCD Display

Detachable Cord

AC Adapter Input

Membrane

9V Alkaline Battery Compartment

S

pecifications

M

odels

SV-30

SV-50

SV-100

Capacity (kg, lbs)

30 kg/66 lbs

50 kg/110 lbs

100 kg/220 lbs

Readability (kg, lbs)

0.005 kg/0.01 lbs 0.01 kg/0.02 lbs 0.02 kg/0.05 lbs

Repeatability

±2d

Weighing Modes

kg, lb & parts counting presets of 5, 10, 25 & 50 pieces

Tare Range

To capacity by subtraction

Calibration 

(NBS Class F)

30kg

50kg

100kg

Stabilization Time 

(sec)

3

Maximum Overload

200.0%

Overload Indication

"E" with audio tone

Underload Indication

Negative value

Auto Off

4 minutes no activity (battery only)

Optimum Operating
Temperature

64˚û - 77˚û F (18-25 C)

Optimum Operating
Humidity

Less than 80% RH

Display Type

LCD/.75" high w/segment test

Audio Tone

On, start up, function keys, overload, low battery

Low Battery Indication

"LO" w/10 beep signal

Power Requirements

9V alkaline or nicad battery, or included AC adapter

Platform Size/Type

12" x 12.5"stainless steel (305 x 315mm)

Dimensions HxWxD

4"x 14.5"x 18.5"(100 x 370 x 470mm)

Net Weight (lb/kg)

12/5.4

Optional Accessories

Calibration mass

Performance specifications measured within optimum temperature range
after recommended warm up and proper calibration.  Specifications subject
to change without notice.

as applicable

Models     SV

Models     SV-30

-30      SV

SV-50

-50     SV

SV -100

-100

Models

Models     SV

SV-30

-30     SV

SV -50

-50     SV

SV -100

-100

Certificate

of Calibration

We hereby certify that this instrument 

was manufactured in the United States

and that it has been calibrated using

appropriate reference standards traceable

to the

 

National Institute of Standards

National Institute of Standards

and Technology.

and Technology.

This instrument has been fully 

inspected and has passed all quality tests

as specified by

Acculab

Acculab quality procedures.

To assure proper measurements, it is 

necessary to periodically recalibrate the

instrument using appropriate standards

as specified in the operating manual.

R

R

P

hone:

800-656-4400
631-254-4299

F

ax :

800-356-0338
631-253-5472

S

a les Office :  

131 Heartland Blvd

 Edgewood, NY 11717

www.acculab.com

400305.1 Rev. A

ACCULAB

ACCULAB

Limited Warranty

Effective Date: January 1, 2003

Standard Terms and Conditions

Models: SV series
ACCULAB warrants the product series "SV" against defects in material and 
workmanship to the original consumer for a peroid of tewnty four (24) months 
or a maximum of thirty (30) months from date of sale to Authorized 
ACCULAB distributor. The warranty includes parts, labor and return shipping 
charges to customer (ground freight).

This specific warranty shall not apply to any product damaged due to accident,
misuse, abuse, lightning strike, power surges, improper packaging for shipment to
ACCULAB, or service/modification by anyone other than an authorized ACCULAB
Technician.

The purchaser's sole remedy, ACCULAB and its suppliers sole liability are set forth
herein. In no event shall ACCULAB or its suppliers be liable for any damages,
incidental or consequential, expenses, lost profits, lost savings, or any other claims
due to the use or inability to use the product/s. ACCULAB shall limit its obligations
under warranty to a time not to exceed the original product warranty period set
forth herein. This warranty gives you specific legal rights and you may have other
rights, which may be different from state to state.

In the event that service is required, the Customer/Distributor should call
ACCULAB (800-656-4400, extension 8342) for proper return authorization. The
product must be delivered to ACCULAB, Service Division 6542 Fig Street, Arvada,
CO., 80004 within the warranty period, freight charges prepaid. The customer is
responsible for product removal, installation and proper packing in order to 
prevent damage while shipping to ACCULAB Service facility. 

This limited warranty supersedes all other warranties pertaining to the ACCULAB
products, whether expressed or implied. Claims may be made by calling 800-656-
4400/631-254-4299, by fax 800-356-0338/631-253-5472, or in writing to:

                                                                         

                                                                                                           Attn: Warranty Administrator

                                                                                                            6542 Fig Street

                                                                                                             Arvada, CO., 80004

                                                                                                               (800-656-4400)  

Summary of Contents for SV-30

Page 1: ...uction Manual PLEASE READ COMPLETE INSTRUCTIONS BEFORE USE Platform LCD Display Detachable Cord AC Adapter Input Membrane 9V Alkaline Battery Compartment Models Models SV SV 30 30 SV SV 50 50 SV SV 10...

Page 2: ...o other electronic equipment can all have an adverse effect on the reliability and accuracy of your unit Handle with care Carefully set weighing pan onto top of unit until level Gently apply all items...

Page 3: ...imately 30 min In addition to the intial setup calibration the factory recommends to recalibrate the scale periodic ally for optimum perfomance Use Class F weights or other equivalent class weights Ca...

Page 4: ...weighed material needs to be held in a con tainer and only the net weight of the material is desired Place the container only without material on the weighingpan wait for a stable reading and then pre...

Page 5: ...TE When the entire load is removed from the balance the dis play will show a negative value equal to the tared value of the con tainer if used To reset the balance to zero press the tare key Press to...

Page 6: ...balance If the sample unit weight for one piece is less than 5X D the display will read Er 1 indicating that the individual 1 piece part weight is too low and must be increased To reset press CAL MOD...

Page 7: ...hipping charges to customer ground freight This specific warranty shall not apply to any product damaged due to accident misuse abuse lightning strike power surges improper packaging for shipment to A...

Page 8: ...ted States and that it has been calibrated using appropriate reference standards traceable to the National Institute of Standards National Institute of Standards and Technology and Technology This ins...

Page 9: ...R Phone 800 656 4400 631 254 4299 Fax 800 356 0338 631 253 5472 Sales Office 131 Heartland Blvd Edgewood NY 11717 www acculab com 400305 1 Rev A...

Reviews: