Acculab Model Numbers

VI-200

VI-350

VI-400

VI-600

VI-1200

VI-2400

VI-4800

VI-4kg

VI-6kg

VI-10kg

CAPACITY

200g 350g 400g

600g

1200g

2400g

4800g

4000g

6000g

10000g

7.054oz 12.345oz 14.10oz

21.16oz

42.32oz

84.65oz

169.31oz

141.0oz

211.6oz

352.7oz

126.602dwt

225.055dwt

257.20dwt

385.80dwt

771.61dwt

1543.23dwt

3086.47dwt

2572.0dwt

3858.0dwt

6430.1dwt

6.430ozt

11.252ozt

12.86ozt

19.29ozt

38.58ozt

77.16ozt

154.32ozt

128.6ozt

192.9ozt

321.5ozt

READABIITY (g)

0.01

0.1

1

PRECISION (g)

±0.01

±0.1

±1

WEIGHING MODES

g, oz, dwt, ozt & parts counting

TARE RANGE

To capacity by subtraction

CALIBRATION

Auto calibration from keypad w/included weight

Auto calibration from keypad 

STABILIZATION 

3 seconds

MAXIMUM OVERLOAD

150% of capacity

OVERLOAD INDICATION

“H” reading on LCD

UNDERLOAD INDICATION

“L” reading on LCD

OPERATING TEMPERATURE

50˚ - 86˚F (10˚ - 30˚C)

OPERATING HUMIDITY

Less than 80% RH

DISPLAY TYPE

LCD / .75” high with segment test

AUDIO TONE

At startup and function keys

POWER REQUIREMENTS

9V alkaline battery

AC adapter 

9V alkaline battery or AC adapter 

or AC adapter

only

PLATFORM SIZE/TYPE

4.5” diameter (115mm), 

5.5”x5.7” (141 x 145mm), stainless steel

stainless steel

DIMENSIONS 

H x W x D

3.5”x5.75”x10.25” (89 x 146 x 260mm)

NET WEIGHT 

(lb/kg)

4/1.8

SECURITY

Built-in lock-down bracket, cable lock sold separately

INCLUDED ACCESSORIES

Calibration weight & AC adapter

AC adapter only

OPTIONAL ACCESSORIES

Cable lock, carry case

Cable lock, calibration weight, carry case

SUPPLIED ACCESSORIES

• Calibration Weight with the following models:

VI-200 - One (1) 200g weight to calibrate balance at 200g OIML Class M1
VI-350 - One (1) 200g weight to calibrate balance at 200g OIML Class M1
VI-400 - One (1) 200g weight to calibrate balance at 200g OIML Class M2
VI-600 - Two (2) 200g weights to calibrate balance at 400g OIML Class M2

• AC Adapter (DC12V)

#AC-1 -For use in USA/Canada (AC 120V  60Hz)
#AC-2 -For use in Europe (AC 240V  50Hz)
#AC-3 -For use in U.K. (AC 240V  50Hz)
#AC-4 -For use in Japan (AC 100V  50/60Hz)
#AC-5 -For use in AUS/NZ (AC 240V  50Hz)

OPTIONAL

ACCESSORIES

• Cable Lock, Carry Case

• Calibration Weight 

VI-1200 - One (1) 1kg weight to calibrate balance at 1000g OIML Class M2
VI-2400 - One (1) 2kg weight to calibrate balance at 2000g OIML Class M2
VI-4800 - Two (2) 2kg weights to calibrate balance at 4000g OIML Class M2
VI-4kg - One (1) 2kg weight to calibrate balance at 2000g OIML Class M2
VI-6kg - Two (2) 2kg weights to calibrate balance at 4000g OIML Class M2
VI-10kg - Three(3) 2kg weights to calibrate balance at 6000g OIML Class M2

Specifications

Performance specifications measured within optimum temperature range after recommended warm up and proper calibration.  
Specifications subject to change without notice.

Model #

• VI-200

• VI-2400

• VI-350

• VI-4800

• VI-400

• VI-4kg

• VI-600

• VI-6kg

• VI-1200 • VI-10kg

page 12

Summary of Contents for VI Series

Page 1: ...VI Series VIR Series Instruction Manual for Models VI 1mg VI 200 VI 2400 VI 3mg VI 350 VI 4800 VI 400 VI 4kg VI 600 VI 6kg VI 1200 VI 10kg 400025 12 Rev B ...

Page 2: ...nd Technology This instrument has been fully inspected and has passed all quality tests as speci fied by Acculab quality procedures To assure proper measurements it is necessary to periodically recalibrate the instrument using appropriate standards as specified in the operating manual Phone 800 656 4400 267 988 8702 Fax 800 356 0338 303 940 2250 Sales Office 67 Buck Road Suite 131 Huntingdon Valle...

Page 3: ...t as clean as possible Electrostatic fields gravitational fields dust dirt moisture vibration air currents and proximity to other electronic equipment can all have an adverse effect on the reliability and accuracy of your unit Handle with care Carefully set weighing tray onto top of unit until level Gently apply all items to be weighed onto the center of tray top Although designed to be quite dura...

Page 4: ...els New housing design directs spills away from the keypad Brushed stainless steel weighing surfaces Built in lock down bracket cable lock sold separately Sealed keypad with raised buttons for tactile feel along with audio function tone Large angled LCD display AC adapter and calibration weights included with all models Housing is constructed of sturdy ABS material with special structural cross br...

Page 5: ...the unit periodically during long periods of use and to always start a procedure by taring the unit to re zero the bal ance External calibration is performed through the use of the key pad controls and proper calibration weight Internal factory calibration is preset and performed by accessing internal components Access to internal components by other than a factory authorized technician will void ...

Page 6: ...procedure When all weight is removed from the weighing tray the tared value of the container will be displayed as a negative number Press the TARE key again to return the balance to zero NOTE The total weight of the container plus material cannot exceed the capacity of the balance Lock Down Bracket A molded piece is attached to the back of the balance housing that can be used on an optional basis ...

Page 7: ... for evaluation 7 E 54 This fault will appear on the display when the unit is powered on This occurs when the electronics are no longer within the factory set parameters The most common cause is from objects being dropped onto the weighing pan or from the balance itself being dropped The balance must be returned to Acculab or an authorized service center for electronic evaluation and repair 8 in t...

Page 8: ... Less than 80 RH DISPLAY TYPE LCD 75 high with segment test AUDIO TONE At startup and function keys POWER REQUIREMENTS AC adapter only included PLATFORM SIZE TYPE 100mm diameter 4 stainless steel DIMENSIONS H x W x D 4 75 x5 75 x10 25 120 x 146 x 260mm NET WEIGHT lb kg 4 1 8 DRAFT SHIELD Glass stainless steel w spill ring SECURITY Built in lock down bracket cable lock sold separately INCLUDED ACCE...

Page 9: ...mplete portability AC adapter included with all models and calibration weights included with all models under 1200g Housing is constructed of sturdy ABS material with special structural cross bracing for added rigidity SECTION 2 For Models VI 200 VI 350 VI 400 VI 600 VI 1200 VI 2400 VI 4800 VI 4kg VI 6kg VI 10kg VIR models include RS 232 interface for computer or printer capability Data output con...

Page 10: ...temperature Always perform the calibration procedure AFTER the unit has been allowed to properly warm up at least 30 minutes It is also recommended to recalibrate the unit periodically during long periods of use and to always start a procedure by taring the unit to re zero the balance External calibration is performed through use of the keypad controls and proper calibration weight Internal fac to...

Page 11: ...lance to zero NOTE The total weight of the container plus material cannot exceed the capacity of the balance Auto Off An auto shut off feature is provided which is operational only while the unit is operating under battery power The unit will automatically turn off after approximately two minutes if no active weighing takes place Auto shut off will not occur during operation with AC Adapter Lock D...

Page 12: ...bable causes of this error code The balance must be returned to Acculab or an authorized service center for electronic evaluation and repair 1 There is something causing the sensor to function out of specification 2 Rough improper handling of the balance 3 Liquids and other materials spilled into the balance NOTE Do not attempt to access internal components or make any unauthorized repairs since t...

Page 13: ... lock sold separately INCLUDED ACCESSORIES Calibration weight AC adapter AC adapter only OPTIONAL ACCESSORIES Cable lock carry case Cable lock calibration weight carry case SUPPLIED ACCESSORIES Calibration Weight with the following models VI 200 One 1 200g weight to calibrate balance at 200g OIML Class M1 VI 350 One 1 200g weight to calibrate balance at 200g OIML Class M1 VI 400 One 1 200g weight ...

Page 14: ...until a beep is heard When the beep sounds the memory buffer is dumped to the LCD and the total sum of everything weighed is visible This also clears out the memory buffer and re initializes it to zero 5 Briefly press TARE PRINT key in order to tare out the balance and you are ready to proceed with normal balance operation A few things to keep in mind If you begin using the memory function and dec...

Page 15: ...segment the number displayed is the setting that is currently selected marked by a small right facing arrow that points to the g indicator on the lower right side of the display 5 To select a new value increment the third segment 2 until you reach the new desired value To lock in this new value press and hold the CAL MODE key until the small right facing arrow appears and points to the g indicator...

Page 16: ...top bits 1 Flow control Hardware 5 Exit back to the main Hyperterminal screen by clicking OK twice The bottom left of your window should say Connected At this point press and hold the TARE PRINT button on the balance The value on the LCD should show up in the Hyperterminal window Controlling The Balance Remotely Via Computer Because the VIR Series RS 232 interface is bi directional a connected com...

Page 17: ...0 Parity 5 2 1 mark 5 2 2 space 5 2 3 odd default 5 2 4 even Stop Bits 5 3 1 1 stop bit default 5 3 2 2 stop bits Handshake 5 4 1 software 5 4 2 hardware w 2 chars after CTS default 5 4 3 hardware w 1 char after CTS Print Stream 6 1 1 manual print regardless of stability 6 1 2 manual print when stable default 6 1 3 continuous print regardless of stability 6 1 4 continuous print when stable Printed...

Page 18: ...alance state ESC O Enable Balance Keypad Changes balance state ESC R Print When Stable Performs a function ESC P Tare Performs a function ESC T Invoke External Calibration Performs a function ESC W Data Interface Cable PIN Configuration For VIR Series Balances RxD 2 TxD 3 Signal Ground 5 Acculab VIR Series Balance 9 PIN port Standard RS 232 9 PIN Connector 3 TxD 2 RxD 5 Signal Ground RxD 2 TxD 3 S...

Page 19: ...bility to use the product s Acculab shall limit its obligations under warranty to a time not to exceed the original product warranty period set forth herein Acculab reserves the right to either repair or replace the balance or scale This warranty gives you specific legal rights and you may have other rights which may be dif ferent from state to state In the event that service is required the Custo...

Page 20: ...ations subject to change without notice as applicable Phone 800 656 4400 267 988 8702 Fax 800 356 0338 303 940 2250 Sales Office 67 Buck Road Suite 131 Huntingdon Valley PA 19006 www acculab com 400025 1 Rev B ...

Reviews: